Abnormal Flame Pattern - Rinnai RHFE 952 ETRN Operation & Installation Manual

Table of Contents

Advertisement

COMMISSIONING

ABNORMAL FLAME PATTERN

After installation and commission, check the flame pattern is normal.
Each Rinnai Gas Fire has a distinct flame pattern. The flame should look the same every time the heater is started,
after an initial warm up period of approximately 15 minutes.
Abnormal flame performance and/or pattern can indicate a problem with the heater, such as blocked gas injectors,
incorrectly installed / inadequate flue system or the Ceramic logs / stones and or burner media may be incorrectly
placed.
If any of the signs below occur, please contact Rinnai.
NORMAL FLAME PATTERN
Key signs of abnormal flame performance:
Appliance turns 'OFF' soon after start up and does not relight.
Continued difficulty or delay in establishing a flame
Flame appears overly orange-yellow.
Flame appears either very short or very long.
Flame only burns part way across the burner.
Severe soot building up on the inside of the glass or on logs.
Continuous unusual smell from the appliance.
Continued difficulty or delay in establishing a flame.
This appliance incorporates a live fuel effect and is designed to operate with luminous flames. This
may leave slight carbon deposition as part of its normal operation.
NOTE
Rinnai
ABNORMAL FLAME PATTERN
40
SOOT BUILD UP
RHFE 952/1253 OIM