11
. COOLING SYSTEM
Connect the upper and lower hoses and
secure them with hose bands.
Connect the overflow tube and secure with
the tube clamp.
Connect the air vent tube to the radiator
filler.
Fill the radiator with coolant.
After install, check for coolant leaks.

WATER PUMP

MECHANICAL SEAL (WATER SEAL)
INSPECTION
Inspect the telltale hole for signs of
mechanical seal coolant leakage.
If the mechanical seal is leaking, remove the
right crankcase cover and replace the
mechanical seal.