Table 15-2: Library SCSI Error Codes
Sense Key
ASC
80h
5h
Illegal
Request
80h
(continued)
80h
81h
81h
81h
Chapter 15. Error Reporting
ASCQ
Error Description
06h
Destination drive is not available.
The medium source is invalid; no bar
07h
code label was detected by the
robotic picker.
18h
Element is reserved.
00h
Duplicate SCSI ID on this bus.
01h
TAP is Exit Only.
Library is full of tapes; no more tapes
02h
may be loaded.
Explanation or Error Remedy
Install/configure drive.
This error occurs when there are no bar
coded tapes in the TAP when running the
Picker Slot Calibration Long Axis Test. This
test requires at least one bar coded tape in
the TAP (any slot) for the diagnostic test to
run.
Re-issue command after the reservation is
cancelled.
All SCSI IDs on a SCSI bus must be unique.
Verify the SCSI ID's of all devices. The host
system bus may have to be rebooted/reset
for the new ID to be accessible.
With Queued Unloads enabled, the TAP is
Exit Only; it can export tapes but not import
them.
1. If you wish to use the software to import
tapes from the TAP to the storage slots, you
must disable the Queued Unloads option.
2. In a multi-partition library, you must
manually load the tapes, using the front
panel Library Controller for single-tape or
bulk loading.
Unload tapes from the library and retry the
operation.
73