Table 4-4: Standard Inquiry Data Field Values - Spectra Logic Spectra S50 User Manual

T-series and 50-series
Table of Contents

Advertisement

Table 4-4: Standard Inquiry Data Field Values

Value
Field Name
Returned
000b
Peripheral
Qualifier
011b
08h
Peripheral
Device Type
1Fh
RMB
1
ISO
00b
ECMA
000b
ANSI
010b
NormACA
0
HiSup
0
Response
2h
Data Format
Additional
n-4
Length
SCCS
0
ACC
0
ALUA
0
1
3PC
0
BQue
0
EncServ
0
VS
0
1
MultiP
0
MChngr
0
Chapter 4. Inquiry—12h
Meaning
The library is a single LUN device. This value is returned only if the LUN sent is 0h.
If the LUN in the ID message is not 0h, this indicates that this LUN is not supported.
Identifies the library as a media changer device, returned only if the LUN sent is 0h.
Returned if the LUN in the ID message is not 0h; it indicates that the LUN is an unknown type.
Indicates media is removable from the library.
The library supports the current ANSI version of the SPC-3 Standard.
The library does not support setting the Normal ACA Supported bit to 1.
The library does not use the hierarchical addressing model to assign LUNs to logical units.
INQUIRY data returned by T-Series and 50-Series libraries conforms to the format defined in
the SPC-3 Standard.
There are n-4 bytes of data following this byte, where n is the last byte returned.
Libraries exported through QIPs return Bytes 0-35 (n=35).
Libraries exported through direct-attached drives return Bytes 0-57 (n=57), with the tape
drive responsible for Bytes 36-57. Refer to the tape drive manufacturer's SCSI specification for
a definition of those bytes and the bits for clocking, QAS, and IUS in Byte 56.
The library does not contain an embedded storage array controller component.
No access controls coordinator may be addressed through this logical unit.
The SCSI target device does not support asymmetric logical unit access or vendor-specific
asymmetric access. Neither REPORT TARGET GROUPS or SET TARGET GROUPS is supported.
Indicates that device support for third-party or EXTENDED COPY commands is enabled.
A 3PC bit of zero indicates that device support for such commands is disabled.
The library does not support tagged tasks (command queuing) for this logical unit.
The library does not contain an embedded enclosure services component.
The library does not support vendor-specific data.
The library's port addressing is overlapped.
The library's port addressing is split.
The library is not embedded within or attached to a medium transport element.
18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Spectra S50 and is the answer not in the manual?

This manual is also suitable for:

T120T50T950

Table of Contents