Command Response
The sense data is valid for the CHECK CONDITION status just presented to the initiator. This
sense data is preserved in the library for the initiator receiving the CHECK CONDITION status.
Sense data is cleared when any subsequent command that is not a REQUEST SENSE or an
INQUIRY (12h) command is received from the initiator. Refer to Chapter 15. Error
Reporting for a list and description of sense codes.
The table below shows the format of the sense data returned by the library.
Table 11-2: Sense Data Format
Bits
Byte
7
00
Valid–1
01
02
03 -
(MSB)
06
07
08 -
(MSB)
11
12
13
14
15
SKSV=0
17
18-51
Chapter 11. Request Sense—03h
6
5
Segment Number–00h (not used)
Reserved for other device types
Additional Sense Length = 2Ch
Command Specific Information–00000000h (not used)
Additional Sense Code (ASC)
Additional Sense Code Qualifier (ASCQ)
Field Replaceable Unit Code—00h
(MSB)
ASCII Representation of Sense
4
3
2
Error code–70h
Information (not used)
Sense-key Specific–not used
55
1
0
Sense Key
(LSB)
(LSB)
(LSB)