Power Terminals; Auxiliary Terminals - Parker 507 Product Manual

Dc controller
Hide thumbs Also See for 507:
Table of Contents

Advertisement

Power Terminals

The product may be connected phase - to - phase provided the resultant
voltage does not exceed the maximum supply voltage specified.
Terminal Function
L1 (L)
AC Input Live
L2 (N)
AC Input Neutral
F+
Field Positive
F-
Field Negative
A-
Armature Negative
A+
Armature Positive
Protective Earth (Ground) Drive Module Protective
Grd
Protective Earth (Ground) Motor Protective Earth
Grd

Auxiliary Terminals

Terminal
Function
A1
Auxiliary Supply
A2
0V - Signal Common Signal Reference
A3
Zero Speed
A4
Health
A5
Zero Speed Level
A6
Auxiliary Setpoint
506/507/508 - HA389427
* The power must be supplied from an independent power supply
which is not earth (ground) referenced.
Description
AC Supply Terminal Line 1
or Live
AC Supply Terminal Line 2
or Neutral
Field Output Positive
Field Output Negative
Armature Output Negative
Armature Output Positive
Earth (Ground)
(Ground)
Description
Auxiliary Relay Supply
Zero Speed Output
Health Output
Zero Speed Output
Level Trim
Auxiliary Direct Speed
Setpoint
Terminal Description
Notes
Notes
+16V at 10mA
Must not be earthed
(grounded)
24V at 50mA open
Collector *
24V at 50mA open
Collector *
For other levels see
Table 3.1
+10V @ 100K Full
Speed Input