Input Power

AC Input AUX Boards
120VAC Input (AT6n50-120)
Grounded
120VAC
Power Source
8-foot Power Cord
(part # 44-000054-01)
provided in the ship kit
Cable Lead Color
Black
White
Green
Power Input:
90-132VAC, 50/60Hz, 1.5A @ 120VAC, single-phase
DC Input (alternative to AC input)
AUX
+5V
GND
+5V
OUT-P
IN-P
GND
ANA
ENBL
GND
1
DC Input AUX Boards
Pins 2 & 5 must not be
*
connected; instead, isolate them
for noise immunity purposes.
2 0
AT6250/AT6450 Installation Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
120VAC-Compatible
AUX Board
Signal
AC Line
AC Neutral
Earth Ground
External 5VDC
Power Supply
+5VDC
Ground
NOTE: If you have an AC version of the AUX board, you
may use this power supply method as an alternative to
the VAC input connection illustrated above.
Screw Terminal Connector
(removable)
5
240VAC Input (AT6n50-240)
Grounded 240VAC
Power Source
1. Remove the cover
on the EIA plug.
2. Build your power
cable as shown.
DO NOT USE A
25mm
120VAC CABLE.
3. Slide the power
6mm
cable into the plug.
4. Connect the
conductor wires.
5. Lock the conductor
wires under the
clamp.
6. Reassemble the
plug.
AC Neutral
Power Input:
90-264VAC, 50/60Hz, 0.75A @ 240VAC, single-phase
Power Input Specification
+5VDC (±5%) @ 1.6A. This provides the power for
all the +5V terminals on all I/O connectors.
DC Power Source Specs
±15VDC Ground (isolate) *
Ð15VDC In
15VDC @ 50mA
+15VDC In
+5VDC Ground (isolate) *
5VDC (±5%) @ 1.6A
+5VDC In
1
User supplied
power cable with
a cross section of
each conductor at
2
1 mm
(18 AWG)
EIA plug
(part # 44-011905-01)
from the ship kit
Clamp
Ground
AC Line

Advertisement