WARNING The ability to properly perform service on
A
this equipment requires certain expertise, mechanical
skills, tools, and equipment. If you do not possess
these, do not attempt to perform any service on this
equipment other than those procedures recommended
in this Manual.
Remote-Wired Control Installation
and Operation
A
CAUTION: Before installing remote controls
to the heaters, read the following: The Heater is
remote-ready. The digital display shows the actual pool
temperature, operating status, and service messages.
See Figure 54. The touch keys on the control panel allows
you to select the desired pool or spa temperature. It also
indicates when a remote system is controlling the heater
by displaying Remote in the display. When connecting
the heater to a remote system, identify whether it is a
two- or three-wire remote system. Select the appropriate
instruction listed below to properly install the remote to
the heater.
Remote-Wired Operation Selector
The heaters are equipped with the ability to work with
external remote controls. The supplied 3-pin remote wiring
connector supplies power out to either a toggle switch or
the switch contacts of a third-party remote. The remote
works by either making or breaking the circuit created
by the remote wiring. Typically, a remote does not supply
power to the heater, it only provides a switching function
to turn the heater On or Off. If your remote is supplying its
own voltage to the heater, it will not work with this heater
and may damage the digital circuit board.
For operation of the heater using the onboard thermostatic
controls with a time clock see "Time Clock/Fireman's
Switch" section on page 38.
Off, SPA and POOL modes
OFF
OFF
Water Temp
68F
Water Temp
68F
SPA Set
90F
Water Temp
68F
Water Temp
68F
Pool Set
Pool Set
85F
85F
Water Temp
Water Temp
85F
85F
REMOTE mode
Remote OFF
Remote OFF
Water Temp
Water Temp
68F
68F
Figure 54. Operation Modes
36
OFF
OFF
No Demand
No Demand
SPA Set
90F
Heating
Heating
Pool Set
85F
No Demand
No Demand
Remote OFF
Remote OFF
No Demand
No Demand
Activating the Remote
To activate or deactivate the remote function, press and
hold the UP and DOWN arrow keys for 3 to 5 seconds.
The second line of the display will alternate even when the
unit is off ("No Demand").
NOTE: When in remote operation, the keypad mode and
temp buttons are disabled.
Remote SPA
90F
Remote SPA
90F
Water Temp
68F
Water Temp
68F
Remote Pool
Remote Pool 85F
85F
Water Temp
Water Temp
85F
85F
Figure 55. Remote Control Menu - Activation
Remote Control Wiring
OBSERVE PRECAUTIONS
SENSITIVE DEVICES
A
CAUTION: Electrostatic Discharge (ESD) damage
can be caused by direct or indirect contact with the
wiring or circuit board. When one walks to the heater
area, an electrostatic charge accumulates on the body.
Contact of a finger allows the body to discharge, possibly
causing device damage. This damage can be limited if
the service person discharges himself, following ESD
preventive/removal practices, and holds on to the heater
enclosure for 5-seconds before proceeding.
Important Installation Notes for Remote or External
Wiring Configuration:
Remote wiring must be run in a separate conduit.
Remote wiring must not be run parallel to high voltage
lines.
For runs of under 30' (9 m), remote wiring should
have stranded conductors with a minimum of 22
AWG, 600V, cable twisting 1.5" to 2.5" (3.8 to 6.4 cm)
lay and jacketed.
For runs over 30' (9 m), the conductors should be a
minimum of 20 AWG, 600V, cable twisting 1.5" to 2.5"
(3.8 to 6.4 cm) lay that is shielded and jacketed.
Maximum cable length is 200' (61 m).
For both two- and three-wire remote systems, the
provided 3-pin wiring connector must be utilized.
Remote SPA
Remote SPA
90F
Heating
Heating
Remote Pool 85F
Remote Pool
85F
No Demand
No Demand
ATTENTION