Program Menu

To access PROGRAM menu, press and hold SERVICE
and MODE keys simultaneously for 5 to 7 seconds until
"Language" appears on the display.
NOTE: Changes to default program configurations
could affect normal functionality of the heater.
Press the SERVICE key sequentially until the desired
program event is reached. By default, there are 12
different settings that can be programmed. Additional
configurations for Flow Sensor, Pump Control and Water
Chemistry are displayed when enabled. Figure 48 lists the
default menus.
Figure 48. Programmable Events
Language Selection
Initial display in PROGRAM Menus is "Language"
selection.
The UP and DOWN keys will select English, Spanish or
French language for all menus and Display messages.
Set Factory Defaults
Press the SERVICE key until it appears on the digital
display. Press and hold SERVICE and MODE keys
simultaneously for 3 to 5 seconds until "Defaults Set"
appears.
This operation resets the operating program to its factory
default values.
Both the POOL and SPA setpoints will revert to 65°F
(18°C) and both POOL and SPA maximum temperature
settings will be 104°F (40°C). Language is set to English,
temperature display is set to Fahrenheit, Automation Mode
is enabled, Altitude to Normal, Flow monitoring is set to
Estimate, Pump Control and Water Chemistry are disabled.
The Control Lockout PIN will be cleared and the control will
resume normal operation. See "Control Lockout" section
on page 34.
Reset Faults
Press the SERVICE key until "Clear Faults" appears on the
digital display. Press and hold SERVICE and MODE keys
simultaneously for 3 to 5 seconds until "Faults Cleared"
appears.
This operation resets the Fault History file to "0" and clears
all the stored faults.
Temperature Display
Press the SERVICE key until "Temp Display" appears
on the digital display. The UP or DOWN keys will select
Fahrenheit or Celsius on the temperature display. Choose
the desired temperature scale.
Spa Setpoint Maximum Adjustment
Press the SERVICE key until "Spa Max. Temp" appears
on the digital display. Using the UP and DOWN keys will
change the Maximum Temperature Setting to your desired
value. The control can be set for a maximum of 107°F
(42°C).
Pool Setpoint Maximum Adjustment
Press the SERVICE key until "Pool Max. Temp" appears
on the digital display. Using the UP and DOWN keys will
change the Maximum Temperature Setting to your desired
value. The control can be set for a maximum of 107°F
(42°C).