Raypak AVIA 264A Installation And Operation Manual page 32

Gas-fired pool and spa heater
Table of Contents

Advertisement

Available languages

Available languages

Wi-Fi Reset
Press the SERVICE key until "Wi-Fi Reset" appears on the
digital display. Press and hold SERVICE and MODE keys
simultaneously for 3 to 5 seconds until "Wi-Fi Initialized"
appears.
This operation resets the Wi-Fi credentials, leaving the unit
ready to configure connection with the Raymote app. For
details on how to connect your pool heater to Raymote,
follow the instructions on page 58.
Automation Mode
Press the SERVICE key until "Automation Mode" appears
on the digital display. The UP or DOWN keys will select
Enabled or Disabled Automation mode functionality. When
an automation routine is active, the display shows an "@"
at the end of Row 1.
Pool Set
Pool Set
85F @
85F @
Water Temp
Water Temp
68F
68F
OFF
OFF
Water Temp
Water Temp
68F
68F
Figure 49. Automation Mode Enabled
By default, Automation Mode is enabled. For details on
how to configure scheduling and automation with Raymote,
refer to page 58.
Flow Monitoring
Press the SERVICE key until "Flow Monitoring" appears
on the digital display. The UP or DOWN keys will select
"Estimation" or "Flow Sensor" on the Flow Monitoring
function.
By default, Flow Monitoring is set to "Estimated". This
function estimates the flow when unit is in "Heating" status.
Flow Sensor is compatible with an optional 5 VDC hall-
effect Flow Sensor. When Flow Sensor option is enabled,
the flow sensor input (P11) translate pulse count of 1 Hz
to 1 GPM. To calibrate, set a gain using the Flow Sensor
Gain submenu.
Flow Sensor Gain
0.1
Figure 50. Submenu – Flow Sensor Gain
32
SPA Set
SPA Set
90F @
90F @
Water Temp
Water Temp
@
@
Flow Sensor Gain
Pump Control
Press the SERVICE key until "Pump Control" appears
on the digital display. The UP or DOWN keys will select
"Enabled" or "Disabled". By default, Pump Mode is
Disabled.
Pump Control is compatible with Raypak RPVSP1 pump.
When "Pump Control" is enabled, the speed configuration
submenus are displayed. Use these submenus to set
predefined pump speeds from 1 to 4.
Pump Speed1
Pump Speed3
Figure 51. Submenu – Pump Speeds
Water Chemistry
68F
68F
Press the SERVICE key until "Water Chemistry" appears
on the digital display. The UP or DOWN keys will select
"Enabled" or "Disabled". By default, Water Chemistry is
"Disabled".
These features are compatible with the Raypak Water
Chemistry kit.
25.5
Pump Speed2
900 RPM
Pump Speed4
2500 RPM
1500 RPM
2900 RPM