Raypak AVIA 264A Installation And Operation Manual page 39

Gas-fired pool and spa heater
Table of Contents

Advertisement

Available languages

Available languages

5 ft. (1.52 m) MAX
POOL OR SPA
MAY REQUIRE ADJUSTMENT
FOR HIGHER PRESSURE
Figure 61. Pressure Switch Adjustment Requirements
Two-Speed Pumps
In some cases, the flow on the low-speed is insufficient
to operate the heater. This is apparent when the water
pressure switch cannot be further adjusted or if the heater
makes banging noises or shuts off on high limit. In these
cases, the pump must be run at high speed when heating
the water.
A
CAUTION: Do not operate the heater without the
function of a properly-adjusted water pressure switch or
flow switch.
Cabinet Limit Switch
Heaters are equipped with a cabinet limit switch to prevent
the overheating of the components inside the cabinet in
case of any flue gas leakage from combustion chamber. It
is a "manual-reset" type switch that must be reset by the
service technician after making sure any leaks or damage
to the unit has been fixed.
Figure 62. Cabinet Limit Switch – Manual-Reset
High Limits
MAY REQUIRE ADJUSTMENT
The heater is equipped with two high limits, both are
FOR LOWER PRESSURE
automatic and are located in the inlet/outlet header.
Although both limits are preset to auto-reset, the control
board will request the operator to press "mode" if either
limit is tripped while the heater is running.
5 ft. (1.52 m)
MAX
High Limit Removal
1. Shut off main electrical power switch to heater.
2. Remove inlet/outlet sheet metal access panel.
3. Remove defective high limit and replace with the
4. Replace access panel.
Adjusting Valve Manifold Pressure
1. Remove the cap to gain access to the adjustment
2. Turn the adjustment screw clockwise to increase
3. The manifold pressure should be negative -0.30
4. Install the cap before reading the manifold pressure.
NOTE: An erratic high limit is often characteristic of an
internal heat exchanger problem, e.g. scale build-up, or
defective bypass. Refer to "Troubleshooting" on page
47.
Figure 63. High Limit Switch
correct, new high limit.
screw.
pressure. (For example, at -0.6" WC turning
clockwise will increase the pressure to -0.5" WC,
-0.4" WC, etc.)
"WC (+/- 0.20 "WC) while running. If a combustion
analyzer is available, the O2 reading should be
between 4.5 - 5.5% O2 while running.
GAS VALVE
MANIFOLD
PRESSURE TAP
Figure 64. Manifold Pressure Adjustment
AUTO-RESET
F10848
39