Raypak 266 Installation And Operation Manual

Raypak 266 Installation And Operation Manual

Gas-fired pool and spa heater, brass asme and polymer atmospheric heat exchanger

Advertisement

INSTALLATION AND
OPERATION MANUAL
Gas-Fired Pool
and Spa Heater
Brass ASME and Polymer
Atmospheric Heat Exchanger Models
206A, 266, 266A, 336A, 399, and 406A
WARNING: If the information in the instructions is not followed exactly, a fire or explosion may result
A
causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors and liquids or other combustible materials in
the vicinity of this or any other appliance. To do so may result in an explosion or fire.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
This manual should be maintained in legible condition and kept adjacent to the heater or in a safe place for future
reference.
Catalog No. 6000.59AH
Effective: 12-16-19
Replaces: 11-15-19
P/N 241236 Rev. 35

Advertisement

Table of Contents
loading

Summary of Contents for Raypak 266

  • Page 1 Spa Heater Brass ASME and Polymer Atmospheric Heat Exchanger Models 206A, 266, 266A, 336A, 399, and 406A WARNING: If the information in the instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 2 QUICK START GUIDE CLEARANCES WATER CHEMISTRY † Space required: See page 12. † Water chemistry requirements: See page 5. † Minimum and service clearances: See page 7 for clearances table. Note that local codes prevail. POWER † Supply voltage: See page 23 for acceptable input voltages.
  • Page 3: Table Of Contents

    CONTENTS 1. WARNINGS ............. 4 6. WIRING DIAGRAM - MILLIVOLT ....... 24 Pay Attention to These Terms ......... 4 7. WIRING DIAGRAM - DIGITAL ......25 2. WATER CHEMISTRY ..........5 8. CONTROLS ............26 Automatic Chlorinators and Chemical Feeders..5 Control Panel Removal .........
  • Page 4: Warnings

    1. WARNINGS Pay Attention to These Terms Indicates the presence of immediate hazards which will cause severe personal injury, death or DANGER substantial property damage if ignored. Indicates the presence of hazards or unsafe practices which could cause severe personal injury, WARNING death or substantial property damage if ignored.
  • Page 5: Water Chemistry

    severely damage the heater. Heat exchanger damage CAUTION: Elevated water temperature can be resulting from chemical imbalance is not covered by hazardous. The U.S. Consumer Product Safety the warranty. Commission has these guidelines: For your health and the protection of your pool equipment, Spa water temperatures should never exceed 104°F it is essential that your water be chemically balanced.
  • Page 6: Before Installation

    3. BEFORE INSTALLATION Rating and certifications These heaters are design-certified and tested under the Receiving equipment latest requirements of the ANSI Z21.56 / CSA 4.7 Standard The manufacturer recommends that this manual be for Gas-Fired Pool Heaters. All heaters can be used either reviewed thoroughly before installing the pool/spa heater.
  • Page 7: Installation

    4. INSTALLATION Installation Codes Installation must be in accordance with local codes, or, WARNING: This unit contains refractory ceramic in the absence of local codes, with the latest edition of fiber (RCF) insulation in the combustion chamber. RCF, the National Fuel Gas Code, ANSI Z223.1/NFPA54 and as manufactured, does not contain respirable crystalline National Electrical Code, ANSI/NFPA 70, and for Canada, silica.
  • Page 8: Outdoor Heater Installation

    When installed according to the listed minimum clearances Clearances less than these may require removal of the from combustible construction, the pool heater can still be heater to service either the heat exchanger or the burner serviced without removing permanent construction around tray.
  • Page 9 For installations in Florida and Texas, that must comply with the Florida or Texas Building Code, follow the directions shown in Figure 5 for the installation of hurricane tie-down brackets for all models. 4' (1.2 m) Minimum Indoor Heater Installation 4' (1.2 m) The heater is also design-certified for indoor installation Minimum...
  • Page 10 FLORIDA AND TEXAS BUILDING CODES WIND SPEED = 150 MPH, 3 SECOND GUST EXPOSURE = C Model in. (mm) 206A 20 (508) 266/266A 23 (584) 336A 26 (660) 399/406A 29 (737) 38" (965 mm) F10648 28" (711 mm) 2" x 6" x 1/8" Pallet Anchor Bracket (4 Total) (Kit# 011636) 3"...
  • Page 11: Combustion And Ventilation Air

    OUTDOOR STACK KIT Model Sq. in. (m (1) Outdoor, painted 206A 200 (0.13) (1) Adapter plate 266/266A 266 (0.17) (3) Mounting brackets (clips) 336A 333 (0.21) (1) Top panel cover 399/406A 399 (0.26) (2) 1-foot sections of metal tape Table E.
  • Page 12 (kw) in. (mm) in. (mm) in. (mm) 199.5 61-5/8 10.0 11-3/4 206A (58.4) (508) (152) (1565) (254) (298) (85) (6.4) 266.0 11.5 266/266A (77.9) (584) (178) (1575) (292) (279) (95) (7.3) 332.5 10-5/8 336A (97.4) (660) (203) (1600) (330)
  • Page 13 (mm) in. (mm) in. (mm) 199.5 61-5/8 10.0 11-3/4 B-_206A-EN-(C or X) (58.4) (508) (152) (1565) (254) (298) (94) (6.4) 266.0 11.5 B-_266A-EN-(C or X) (77.9) (584) (178) (1575) (292) (279) (104) (7.3) 332.5 10-5/8 B-_336A-EN-(C or X) (97.4) (660)
  • Page 14: Vent Piping

    120 VAC P/N 240 VAC P/N Fuel Gas Code and local requirements. 206A 010744 009832 Vent piping the same size as the drafthood outlet is 266/266A 010744 009832 recommended, however, when the total vent height is at 336A 010745 009833...
  • Page 15: Gas Supply Connections

    Gas piping must have a sediment trap ahead of the 8' (2.4 m) heater gas controls, and a manual shut-off valve located OR LESS outside the heater jacket. All gas piping should be tested VENT CAP 2' MIN after installation in accordance with local codes. (0.6 m) CAUTION: The heater and its manual shut-off valve must be disconnected from the gas supply during any...
  • Page 16 Gas Pressure Adjustment Locations Millivolt Gas Valve PRESSURE ADJUSTMENT Figure 14. Robertshaw 7000 (Heater Models 206A - 406A) Electronic Ignition Gas Valves GAS PRESSURE ADJUSTMENT GAS PRESSURE ADJUSTMENT Figure 17. Robertshaw 7000 BDER (Heater Models 266A - Figure 15. Honeywell VR8340 (Heater Models 206A - 406A) 336A) GAS PRESSURE ADJUSTMENT PRESSURE...
  • Page 17: Flow Rate

    9.2 (2.8) 206A 1-1/4"–1-1/2"–2" 20 (75) 125 (473) 80 (303) 4.6 (1.4) 9.2 (2.8) 9.8 (3.0) 9.8 (3.0) 266/266A 1-1/4"–1-1/2"–2" 25 (95) 125 (473) 90 (340) 6.9 (2.1) 10.4 (3.2) 10.4 (3.2) 10.4 (3.2) 100 (378) 8.1 (2.5) 11.0 (3.4) 12.1 (3.7)
  • Page 18: Protek Shield Assembly

    Pressure Drop (Ft. of Head) (m of Head) O-RING Flow GPM (lpm) HEADER FLANGE 206A 266A 336A 406A (CPVC) 20 (75) HEADER FLANGE NUT (CPVC) 30 (113) 40 (151) 13.4 50 (189) 12.2 13.4 60 (227) 10.4 13.7 13.5 HEADER 70 (265) 11.5 10.9...
  • Page 19: Unitherm Governor Operation

    NOTE: Make sure the O-ring is properly seated in the BYPASS DISC O-ring groove before installation. SPRING "YELLOW" - 206/266 Unitherm Governor Operation "GREEN" - 336/406 CAUTION: The patented Unitherm Governor is F10642-3 a thermostatic mixing valve specifically designed to Figure 26.
  • Page 20: Auxiliary Bypass Valve Adjustment

    Auxiliary Bypass Valve Adjustment NOTE: To avoid water damage or scalding due to valve operation, drain pipe must be connected to valve outlet To set bypass, with clean filter, adjustment is made by and run to a safe place of discharge. Drain pipe must feeling the inlet and outlet pipes at the heater.
  • Page 21: Plumbing Diagrams

    Plumbing Diagrams Water Connection ISOLATION VALVE BALL VALVE PRESSURE RELIEF VALVE THIS DIAGRAM IS A RECOMMENDATION AND IS NOT INTENDED TO REPACE AN ENGINEERED PIPING SYSTEM BY A PROFESSIONAL ENGINEER PUMP Figure 31. Single Pool Heater Installation UNION CHECK VALVE THIS DIAGRAM IS A RECOMMENDATION AND IS NOT INTENDED TO REPACE AN ENGINEERED PIPING SYSTEM BY A PROFESSIONAL ENGINEER Figure 32.
  • Page 22: Electrical Wiring

    2. Disconnect wires at high limit, AGS (automatic gas 5. Reconnect high limit, AGS, water pressure switch shut-off), water pressure switch on the in/out header wires, and ProTek Shield bonding wire. and ProTek Shield bonding wire. See Figure 33. 6. Digital Models: Insert the temperature sensor into the compression fitting, so that the sensor is flush with the top of the fitting.
  • Page 23: Electrical Power Draw

    8. Re-route all high-voltage wires and ground wires There should be no connection to the red wire for 120 through the left jacket side of heater. VAC operation. Attach a wire nut to the red wire. 9. Re-install P6 connector, ground wires (SPG), transformer, junction box, front door, and plug right BLACK BLACK...
  • Page 24: Wiring Diagram - Millivolt

    6. WIRING DIAGRAM - MILLIVOLT...
  • Page 25: Wiring Diagram - Digital

    7. WIRING DIAGRAM - DIGITAL...
  • Page 26: Controls

    8. CONTROLS NOTE: Caution must be used to not damage controls or wiring. PRESSURE SWITCH TEMP SENSOR CONTROL HL1 - HIGH LIMIT BEZEL HL2 - HIGH LIMIT KNURLED UNITHERM SCREW GOVERNOR F10646-5 Figure 41. Knurled Screw Location Control Adjustments - ROLL-OUT SWITCH PROTEK...
  • Page 27: Control Adjustments - Digital Models

    Control Adjustments – Digital Models The pool heater touchpad, located on the upper front panel of the heater, allows the user to select either POOL or SPA operation, and to adjust the setpoint temperature. The LCD display window indicates the mode (OFF, SPA, POOL) and the actual water temperature.
  • Page 28 Press the DOWN button. The Fault History displays up to Both the POOL and SPA setpoints will revert to 65°F (18°C) ten faults in memory. The order of the faults begins with and both POOL and SPA maximum temperature settings “Fault Last,”...
  • Page 29: Status And Diagnostics

    The following conditions are displayed only while there is a NOTE: Both the POOL and SPA setpoints will revert demand for heat present. back to 65°F (18°C) and the POOL and SPA maximum temperature settings will be 104°F (40°C). These Display Condition setpoints will need to be readjusted to desired settings.
  • Page 30: Remote Control Wiring - Digital Models Only

    Millivolt models are not designed for operation with remote Remote Control Installation and Operation control sytem. CAUTION: Before installing remote controls to Activating the Remote the digital heaters, read the following: The digital To activate or deactivate the remote function: thermostat model is remote-ready in most cases.
  • Page 31 • For both two- and three-wire remote systems, the 3. Turn the MODE button to “OFF” and remove power provided 7-pin wiring connector must be utilized. from the heater. NOTE: The remote wires must be connected to the 7-pin connector before the connector is plugged into the board.
  • Page 32 For millivolt heaters, the fireman's switch connection is 8. While the heater is running, check the adjustment a wire nut located in the Violet/Black wiring between the by turning the pump off and on several times. The manual toggle switch and the gas valve. heaters, splice burners should shut off immediately when the pump into the red/white wire to connect the time clock.
  • Page 33 Pilot Safety - Millivolt Models CAUTION: Do not operate the heater without the function of a properly adjusted water pressure switch Heaters equipped with the standing pilot (millivolt system) or flow switch. employs a pilot which act as a safety device to shut down the flow of gas to the main burners and the pilot burner in Flame Roll-Out Safety Switch case the pilot flame is extinguished.
  • Page 34 4. Turn vertical gas pipe from manifold slightly and Heat Exchanger Removal unscrew gas valve. 1. Shut water, gas and electricity off, close valves and 5. Reverse above procedure to reinstall. relieve pressure, then remove relief valve. Remove side access panels. Main Burner And Orifice Removal 2.
  • Page 35 1. Remove top and flue collector from cabinet. 2. Remove “V” baffles from heat exchanger. 3. Remove burner tray. See page 33. 4. If ProTek Shield Assy is attached to the heater, F10670 remove ProTek Shield Assy bonding wire from heat exchanger stud.
  • Page 36: Operating Instructions

    9. OPERATING Visual inspection INSTRUCTIONS With the heater on, remove the door and make a visual check of the pilot and burner. The flame should be blue with a well-defined pattern. Before Start-Up A yellow or “floating” flame indicates restricted air openings or incorrect orifice size.
  • Page 37 OPERATING INSTRUCTIONS AND SHUT-OFF PROCEDURES MILLIVOLT SYSTEM (MANUALLY-LIGHTED PILOT) FOR YOUR SAFETY READ BEFORE LIGHTING This appliance has a pilot which must be lit *If you cannot reach your gas supplier, call the by hand. When lighting the pilot, follow these fire department.
  • Page 38 Honeywell valve: Turn INLET control knob clockwise “OFF”. For Robertshaw valve: Models 266-406: Turn gas control knob clockwise to “OFF”. Model ROBERTSHAW 7000 206 Push in and move gas control lever counter- GAS VALVE IID clockwise to “OFF” position. 7. Wait 5 minutes to clear out any gas. If you then smell gas, STOP! Follow "B"...
  • Page 39: Maintenance And Care

    10. MAINTENANCE AND CARE Cold Weather Operation WARNING: Check the heater for possible rodent Important Freeze Information nests after long periods of non-use. MODERATE CLIMATE: Heater operation can continue during short-term cold spells. When temperatures are To be followed one month after start-up and then semi- between 0°F (-18°C) and 32°F (0°C), flow (continuous annually.
  • Page 40: Troubleshooting

    11. TROUBLESHOOTING IMPORTANT NOTICE: These instructions are intended for the use of qualified personnel who are specifically trained and experienced in the installation of this type of heating equipment and related system components. Installation and service personnel may be required by some states to be licensed. Persons not qualified shall not attempt to install this equipment nor attempt repairs according to these instructions.
  • Page 41: Millivolt - Flow Chart

    Millivolt - Flow Chart Light pilot If pilot burner If pilot burner goes out If pilot burner remains lit does not light when main burner lights or when gas valve knob is released Jump across both "TH" Check gas supply, gas wires on gas valves line size, gas pressure.
  • Page 42: Digital - Flow Chart

    Digital - Flow Chart WARNING: HIGH VOLTAGE For qualified technicians ONLY NOTE: Some heaters may be equipped with an ignition module that shuts off pilot gas if pilot fails to light. To reset, interrupt power to heater. START TURN GAS SUPPLY OFF. NOTE: Before troubleshooting, familiarize yourself with the start-up and check-out TURN THERMOSTAT procedure.
  • Page 43: Control Logic - Flow Chart - Digital

    Control Logic - Flow Chart - Digital Power On • Check On/Off switch (under lid on control panel) Is the water • Check for 120/240 volts to the transformer temperature displayed? (time clock, circuit breaker, wire connections) • Check for 24 volts to Circuit Board (P6 connector) “Remote”...
  • Page 44: Replacement Parts

    12. REPLACEMENT PARTS NOTE: To supply you with the correct part, it is important that you supply the heater model number, serial number and type of gas when applicable. Any part returned for replacement under standard company warranties must be properly tagged with a return parts tag, completely filled in with the heater serial number, model number, etc., and shipped to the Company freight prepaid.
  • Page 45: Illustrated Parts List

    13. ILLUSTRATED PARTS LIST 14-M I3-S 2 -S 6-HP 5-HP 7-HP 15-HP 2-HP 3-HP 7-HP 6-HP 4-HP 8 -C I 2-S 14-M 20- HP 17- HM 11- S 1 0 -M 4- S 25-M 18-M 2 -M 11-M 2-B 5-M 13-M 2- J 12-M...
  • Page 46 19-M (OPTIONAL) 8-HP 20-M 8-HP 21-M 6-HM 27-HM 5-HM 26-HM 2-HM 7-HM 3-HM 4-HM 28-HM 18-HP 17-HP 20-HP FOR UNITS WITH ASME BRASS HEADERS FROM 12/2019 (PROTEK SHIELD NOT AVAILABLE ON ASME HEATERS UNTIL MARCH 2020) ( O P T I O N A L ) 14-HM 16-HM 13-HM...
  • Page 47 19-HP 19-HP (OPTIONAL) (OPTIONAL) 19-HP 11-HP 11-HP 8-HP 18-HP 16-HP 12-HP 8-HP 10-HP 10-HP 16-HP 12-HP 15-HP 18-HP 2-HP 2-HP 13-HP 14-HP 13-HP 17-HP 20-HP 14-HP 17-HP FOR UNITS WITH POLYMER HEADERS PRIOR TO 10/2019 F O R UNITS W IT H PO LYM E R HE AD E R S F R OM 1 0/ 20 19 HONEYWELL MILLIVOLT PILOT HONEYWELL IID ATMOSPHERIC PILOT 19-M...
  • Page 48 CALL OUT DESCRIPTION 206A 266/266A 336A 399/406A BURNER TRAY Burner Tray w/Burners (sea level)* 010391F 010392F 010393F 010394F Burner Tray w/o Burners (sea level)* 010395F 010396F 010397F 010398F Burner Tray w/Gas Valve Nat Millivolt 010399F 010400F 010401F 010402F Burner Tray w/Gas Valve Pro Millivolt...
  • Page 49 Nut - ProTek Shield Adapter - 2-Pc from 3/2020 018007F 018007F 018007F 018007F 28-HM U.G./Bypass Assembly 017958F 017958F 017962F 017962F CALL OUT DESCRIPTION 206A 266/266A 336A 399/406A CONTROL BOX Transformer 120/240/24V 006736F 006736F 006736F 006736F Rocker Switch 009493F 009493F 009493F 009493F MISCELLANEOUS COMPONENTS Pressure Switch 1.75 PSI...
  • Page 50 CALL OUT DESCRIPTION 206A 266/266A 336A 399/406A PILOT Pilot Nat. MV 600525B 600525B 600525B 600525B Pilot Pro. MV 600575B 600575B 600575B 600575B 002003F 002003F 002003F 002003F Pilot Nat & Pro IID Pilot Orifice Nat. MV 003901F 003901F 003901F 003901F Pilot Orifice Pro. MV...
  • Page 51 NOTES...

Table of Contents