Installation Codes; Clearances; Outdoor Heater Installation - Raypak AVIA 264A Installation And Operation Manual

Gas-fired pool and spa heater
Table of Contents

Advertisement

Available languages

Available languages

WARNING: Improper installation, adjustment,
A
alteration, service or maintenance may damage the
equipment, create a hazard resulting in asphyxiation,
explosion or fire, cause damage which will not be
covered under warranty.

Installation Codes

Installation must be in accordance with local codes, or,
in the absence of local codes, with the latest edition of
the National Fuel Gas Code, ANSI Z223.1/NFPA54 and
National Electrical Code, ANSI/NFPA 70, and for Canada,
the latest edition of CAN/CSA-B149 Installation Codes,
and Canadian Electrical Code, CSA C22.1 Part 1 and
Part 2.
A
AVERTISSEMENT: Cet appareil doit être installé
conformément au National Fuel gas Code ANSI Z223.1,
et aux exigences de l'autorité competente.

Clearances

All Heaters
For indoor and outdoor clearances from combustible
surfaces see Table B below.
Location
Top
Unobstructed
Front
0"
Floor
0"
Back
0"
Right Side
3" (76 mm) from Panel - Water Side
Left Side
3" (76 mm) from Panel - Vented Side
Location
Top
Unobstructed
Front
0"
Floor
0"
Back
0"
Right Side
3" (76 mm) from Panel - Water Side
Left Side
6" (152 mm) from Vent Cap
Table B.
Minimum Clearances from Combustible Surfaces
For ease of servicing, we recommend a clearance of at
least 24" (610 mm) for both the left and right side, and
also the top. This will enable the heater to be serviced in
its installed location, that is, without needing to move the
header.
Clearances less than these may require removal of the
heater to service either the heat exchanger or the burner.
In either case, the heater must be installed in a manner
that will enable the heater to be serviced without removing
any structure around the heater.
Indoor Installation
Outdoor Installation
Flooring
This heater can be installed on combustible flooring.

Outdoor Heater Installation

These heaters are design-certified for outdoor installation,
when equipped with the approved vent cover designated
for outdoor use.
A
WARNING: The heater shall not be located in an
area where water sprinklers, or other devices, may cause
water to spray through the cabinet louvers and into the
heater. This could cause internal rusting or damage
electrical components, and void the warranty.
A
WARNING: Do not install within 3' (0.9 m) of a heat
pump or an outdoor condensing unit. Strong air intake
from this type of equipment can disturb the combustion
process and cause damage or personal injury.
OUTDOOR
VENT COVER
Figure 2.
Front View Of Cabinet Vent/Air Inlet Termination
Clearances
INLET
OUTLET
7