D. Cut each segment of cable to meet your planned needs.
WARNING: Do not install the modules in a way that creates continuous tension on the IQ Cable.
E. Connect the IQ Cable to the AC junction box. The IQ Cable uses the following wiring color code:
Black = L1, Red = L2.
Step 3: Terminate the unused end of the cable
Place IQ Sealing Caps on unused connectors and terminate the unused end of the IQ Cable as follows.
A. Cover any unused connectors with IQ Sealing Caps. Listen for a click as the connectors
engage.
WARNING: Risk of electric shock. Risk of fire. Install sealing caps on all unused AC connectors
as these connectors become live when the system is energized. Sealing caps are required for
protection against moisture ingress.
NOTE: If you need to remove a sealing cap, you must use the IQ Disconnect Tool. For more
information, refer
B. Remove 13 mm (½ inch) of the cable sheath from the conductors. Use the terminator loop
to measure 13 mm.