Installing A Power Supply Unit; Removing A Non-Redundant Cabled Ac Power Supply Unit - Dell EMC PowerEdge R450 Xeon 4309Y Installation And Service Manual

Table of Contents

Advertisement

Next steps
Installing a processor and heat sink module

Installing a power supply unit

The procedure for installing AC and DC PSUs is identical.
Prerequisites
1. Follow the safety guidelines listed in
2. For systems that support redundant PSU, ensure that both the PSUs are of the same type and have the same maximum
output power.
NOTE:
The maximum output power (shown in watts) is listed on the PSU label.
Steps
Slide the PSU into the system until the PSU is fully seated and the release latch snaps into place.
Figure 118. Installing a power supply unit
Next steps
1. If you have unlatched the cable management arm, relatch it. For information about the cable management arm, see the
system's rack documentation at www.dell.com/poweredgemanuals.
2. Connect the power cable to the PSU, and plug the cable into a power outlet.
CAUTION:
When connecting the power cable to the PSU, secure the cable to the PSU with the strap.
NOTE:
When installing, hot swapping, or hot adding a new PSU, wait for 15 seconds for the system to recognize the
PSU and determine its status. The PSU redundancy may not occur until discovery is complete. Wait until the new PSU is
discovered and enabled before you remove the other PSU. The PSU status indicator turns green to signify that the PSU
is functioning properly.

Removing a non-redundant cabled AC power supply unit

Prerequisites
1. Follow the safety guidelines listed in
2. Follow the procedure listed in
118
Installing and removing system components
Safety
instructions.
Safety
instructions.
Before working inside your
system.