Dell EMC PowerEdge R450 Xeon 4309Y Installation And Service Manual page 11

Table of Contents

Advertisement

Table 3. Left control panel
Item
Indicator, button, or
connector
1
Status LED indicators
System health and system
2
ID indicator
iDRAC Quick Sync
3
2 wireless indicator
(optional)
Status LED indicators
NOTE:
The indicators display solid amber if any error occurs.
Table 4. Status LED indicators and descriptions
Icon
Description Condition
Drive
The indicator turns solid amber if
indicator
there is a drive error.
Temperature
The indicator turns solid amber
indicator
if the system experiences a
thermal error (for example, the
ambient temperature is out of
range or there is a fan failure).
Electrical
The indicator turns solid amber
indicator
if the system experiences an
electrical error (for example,
voltage out of range, or a failed
power supply unit (PSU) or
voltage regulator).
Memory
The indicator turns solid amber if
indicator
a memory error occurs.
PCIe
The indicator turns solid amber
indicator
if a PCIe card experiences an
error.
Icon
Description
N/A
Indicate the status of the system. For more information, see the
Status LED indicators
Indicates the system health.
Indicates if the iDRAC Quick Sync 2 wireless option is activated.
The Quick Sync 2 feature allows management of the system
using mobile devices. This feature aggregates hardware/
firmware inventory and various system level diagnostic/error
information that can be used in troubleshooting the system.
You can access system inventory, Dell Lifecycle Controller
logs or system logs, system health status, and also configure
iDRAC, BIOS, and networking parameters. You can also launch
the virtual Keyboard, Video, and Mouse (KVM) viewer and
virtual Kernel based Virtual Machine (KVM), on a supported
mobile device. For more information, see the Integrated
Dell Remote Access Controller User's Guide at
poweredgemanuals
Corrective action
● Check the System Event Log to determine if the drive has an
error.
● Run the appropriate Online Diagnostics test. Restart the system
and run embedded diagnostics (ePSA).
● If the drives are configured in a RAID array, restart the system,
and enter the host adapter configuration utility program.
Ensure that none of the following conditions exist:
● A cooling fan has been removed or has failed.
● Ambient temperature is too high.
● External airflow is obstructed.
If the problem persists, see
Check the System Event Log or system messages for the specific
issue. If it is due to a problem with the PSU, check the LED on the
PSU. Reseat the PSU.
If the problem persists, see
Check the System Event Log or system messages for the location of
the failed memory. Reseat the memory module.
If the problem persists, see
Restart the system. Update any required drivers for the PCIe card.
Reinstall the card.
If the problem persists, see
NOTE:
Expansion card installation
section.
.
Getting
help.
Getting
help.
Getting
help.
Getting
help.
For more information about the supported PCIe cards, see
guidelines.
Dell EMC PowerEdge R540 overview
www.dell.com/
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Emc poweredge r540

Table of Contents