Removing The Right Control Panel - Dell EMC PowerEdge R450 Xeon 4309Y Installation And Service Manual

Table of Contents

Advertisement

Figure 124. Installing left control panel
Next steps
1.
Installing the air shroud
2.
Installing PERC card into the internal PERC riser
3. Follow the procedure listed in

Removing the right control panel

Prerequisites
1. Follow the safety guidelines listed in
2. Follow the procedure listed in
3.
Removing the PERC card from the internal PERC riser
Steps
1. Lift the cable latch and disconnect the control panel cable from the connector on the system board.
NOTE:
Ensure that you note the routing of the cables as you remove them from the system board. You must route the
cables properly when you replace them to prevent the cables from being pinched or crimped.
2. Using Phillips #1 screwdriver, remove the screws that secure the right control panel assembly to the system.
126
Installing and removing system components
After working inside your
Safety
instructions.
Before working inside your
system.
system.

Advertisement