Removing A Power Supply Unit Blank; Installing A Power Supply Unit Blank - Dell 5J5D0 Installation And Service Manual

Table of Contents

Advertisement

● If the load on the active PSU is more than 50 percent of PSU rated power wattage, then the redundant PSU is switched to
the active state.
● If the load on the active PSU falls below 20 percent of PSU rated power wattage, then the redundant PSU is switched to
the sleep state.
You can configure the hot spare feature by using the iDRAC settings. For more information, see the iDRAC User's Guide
available at www.dell.com/poweredgemanuals.

Removing a power supply unit blank

Prerequisites
Follow the safety guidelines listed in the
Steps
Pull the blank out of the system.
CAUTION:
To ensure proper system cooling, the PSU blank must be installed in the second PSU bay in a
non-redundant configuration. Remove the PSU blank only if you are installing a second PSU.
Figure 90. Removing a power supply unit blank
Next steps
Replace the
PSU
or
PSU

Installing a power supply unit blank

Prerequisites
1. Follow the safety guidelines listed in the
NOTE:
Install the power supply unit (PSU) blank only in the second PSU bay.
2.
Remove the
PSU.
Steps
Align the PSU blank with the PSU bay and push it into the PSU bay until it clicks into place.
Safety
instructions.
blank.
Safety
instructions.
Installing and removing system components
91

Advertisement

Table of Contents
loading

This manual is also suitable for:

Emc poweredge r6515

Table of Contents