Front Panel Menus - At A Glance - Agilent Technologies 66311A User Manual

Table of Contents

Advertisement

1 - Quick Reference

Front Panel Menus - At a Glance

Address
ADDRESS 7
INTF HPIB
BAUDRATE 300
PARITY NONE
FLOW NONE
LANG SCPI
REMOTE FP OFF
Recall
*RCL 0
Shift
Save
*SAV 0
Shift
Error
ERROR 0
Meter
12.000V 0.204A
12.500V MAX
1.000V MIN
12.330V HIGH
0.080V LOW
12.000V RMS
0.350A MAX
0.050A MIN
0.400A HIGH
0.012A LOW
0.210A RMS
Voltage
VOLT 20.000
Current
CURR 2.000
Protect
OC -- -- -- --
Output
*RST
PON:STATE RST
PROT:DLY 0.08
RI LATCHING
DFI OFF
DFI:SOUR OFF
PORT RIDFI
DIGIO 7
TYPE:CAP LOW
Shift
OV
VOLT:PROT 22
PROT:STAT ON
Shift
Input
CURR:RANG HIGH
CURR:DET ACDC
TINT 46.8
POINT 2048
Shift
Cal
CAL ON
Use
and
to select parameters (table shows factory defaults).
6
Sets the HP-IB Address
Selects an interface (HPIB or RS232)
Selects baud rate (300, 600, 1200, 2400, 4800, 9600)
Selects message parity (NONE, EVEN, ODD, MARK, SPACE)
Selects flow control (XON-XOFF, RTS-CTS, DTR-DSR, NONE)
Selects language (SCPI or COMP)
Enables or disables HP 14575A front panel interface (ON or OFF)
Recalls instrument state
Saves present instrument state
Displays errors in SCPI error queue
Measures output voltage and current
Measures peak output voltage
Measures minimum output voltage
Measures the high level of a voltage pulse waveform
Measures the low level of a voltage pulse waveform
Measures rms voltage
Measures peak output current
Measures minimum output current
Measures the high level of a current pulse waveform
Measures the low level of a current pulse waveform
Measures rms current
Sets the output voltage
Sets the output current
Protection status (example shows overcurrent tripped)
Places the dc source in the factory-default state
Select the power-on state command (RST or RCL0)
Sets the output protection delay in seconds
Sets the remote inhibit mode (LATCHING, LIVE, or OFF)
Sets the discrete fault indicator state (ON or OFF)
Selects the DFI source (QUES, OPER, ESB, RQS, or OFF)
Sets the output port functions (RIDFI or DIGIO)
Sets and reads the I/O port value (0 through 7)
Sets the output capacitance compensation (HIGH or LOW)
Sets the overvoltage protection level
Enables or disables overvoltage protection (ON or OFF)
Sets the current range (HIGH, LOW, or AUTO)
Sets the current measurement detector (ACDC or DC)
Sets the time interval for a front panel measurement in seconds
Sets the buffer size for a front panel measurement
Accesses calibration menu (See Appendix B).
Meter
Use
to exit any menu.