Front Panel Menus - At a Glance

Address
ADDRESS 7
LANG SCPI
ROM: A.00.00
SN: US12345678
Recall
*RCL 0
Shift
Save
*SAV 0
Shift
Error
ERROR 0
Channel
5.000V 0.104A
Shift
2
Meter
12.000V
1
12.500V MAX
1
1.000V MIN
1
12.330V HIGH
1
0.080V LOW
1
12.000V RMS
1
0.350A MAX
1
0.050A MIN
1
0.400A HIGH
1
0.012A LOW
1
0.210A RMS
1
12.000V DC:DVM
1
12.000V RMS:DVM
1
Voltage
VOLT 12.000
1
VOLT 2.000
2
Current
CURR 2.000
1
CURR 1.000
2
Shift
Res
RES 1.000
1
Protect
OVERCURRENT
Output
*RST
COUPLING ALL
COMP LLOCAL
PON:STATE RST
PROT:DLY 0.08
RI LATCHING
DFI OFF
DFI:SOUR OFF
PORT RIDFI
DIGIO 7
SENSE:PROT OFF
REL:MODE DD
1
Shift
OV
VOLT:PROT 10.000
PROT:STAT ON
Shift
Input
CURR:RANG MAX
CURR:DET ACDC
TINT 46.8
POINT 2048
Shift
Cal
CAL ON
Use
and
to select parameters (table shows factory defaults).
1
Only valid for Agilent Model 66319B/D
Sets the GPIB Address
Selects language (SCPI)
Displays the firmware revision of the instrument
Displays the serial number of the instrument
Recalls the instrument state
Saves the present instrument state
Displays the number of errors in the SCPI error queue
Toggles the display between output 1 and output 2 (output 2 shown)
0.204A
Measures the output voltage and current (output 1 shown)
1
Measures the peak output voltage
Measures the minimum output voltage
Measures the high level of a voltage pulse waveform
Measures the low level of a voltage pulse waveform
Measures the rms voltage
Measures the peak output current
Measures the minimum output current
Measures the high level of a current pulse waveform
Measures the low level of a current pulse waveform
Measures the rms current
Measures the dc voltage on the DVM input
Measures the rms voltage on the DVM input
Sets the voltage of output 1 on all models
Sets the voltage of output 2
Sets the current limit of output 1 on all models
Sets the current limit of output 2
Sets the resistance of output 1 on all models
Protection status (example shows overcurrent tripped)
Places the dc source in the factory-default state
Couples or decouples output 1 and output 2 (NONE or ALL)
Sets the output compensation (HREMOTE, LREMOTE, HLOCAL or LLOCAL)
Select the power-on state command (RST or RCL0)
Sets the output protection delay in seconds
Sets the remote inhibit mode (LATCHING, LIVE, or OFF)
Sets the discrete fault indicator state (ON or OFF)
Selects the DFI source (QUES, OPER, ESB, RQS, or OFF)
Sets the output port functions (RIDFI, DIGIO, or TRIGGER)
Sets and reads the I/O port value (0 through 7)
Enables or disables the open sense lead detect circuit (ON or OFF)
Sets the relay mode for Option 521 units (DD, HD, DH, or HH) (output 1 shown)
Sets the programmable voltage limit for output 1
Enables or disables overvoltage protection for output 1 (ON or OFF)
Sets the current range (3A, 1A, 0.02A, or AUTO)
Sets the current measurement detector (ACDC or DC)
Sets the time interval for a front panel measurement in seconds
Sets the buffer size for a front panel measurement
Accesses calibration menu (See Appendix B)
2
Only valid for Agilent Model 66321D/66319D
1
1
2
2
Use
to exit any menu.
Meter
Quick Reference - 1