E – Line Voltage Conversion
white/red/grey
orange
orange
grey
grey
orange
orange
white/red/grey
Figure E-1, Power Transformer AC Input Connections

Install the Correct Line Fuse

Unscrew the line fuse cap from the rear panel and install the correct fuse.
For 100/120 Vac operation: 2 A slow-blow; HP part number 2110-0303
For 220/230 Vac operation: 1 A slow-blow; HP part number 2110-0007
Mark the voltage setting that the unit has been set to on the rear panel label.

Close the Unit

Replace the outer cover.
Reconnect the power cord and turn on the unit.