Checking the instrument output

N O T E
U8030A Series User's Guide
2 Verify the power- line voltage setting.
The line voltage is set to the proper value for your
country when the power supply is shipped from the
factory. Change the voltage setting if it is not correct. The
settings are: 100, 115, or 230 V
3 Verify that the correct power- line fuse is installed.
The correct fuse for your country is installed when the
power supply is shipped from the factory. See the table
below to replace the fuse for your power supply.

Table 1-1 List of rated fuse for line voltages

Model
Agilent part number
U8031A/
2110-1504
U8032A
The following procedures check to ensure that the power
supply develops its rated outputs and properly responds to
operation from the front panel. For complete performance
and verification tests, refer to the U8030A Series Service
Guide.
From the front- panel VFD (vacuum- fluorescent display), you
can monitor actual values of output voltage and current
(meter mode) or voltage and current limit values (limit
mode).
If an error is detected during the output checkout procedure, the Err
annunciator will turn on. For more information, refer to the
Codes"
on page 35.
Introduction
Preparing Your Power Supply
.
AC
Part description
FUSE 1.0 A TIME-DELAY 0.0757 Ω
20 mm × 5.2 mm × 5.2 mm
"List of Error
1
21