(3). Close the Fuel Cap tightly.
(4). Turn OFF the Fuel Cap Vent Lever.
DO NOT turn the Fuel Cap Vent Lever to "OFF" position
before cooling the engine.
not, the fuel tank can be crushed by cold contraction of the
fuel gas in the fuel tank.
Keep all cooling holes open and clear of debris, mud, water, etc.
Cooling holes are located on the front panel and the back cover
of generator. If the cooling holes are blocked, the generator
may overheat and damage the engine, inverter, or windings.
DO NOT remove any cover of the Generator Case 1 when the
engine is running. If not, inverter or other electric parts may be
damaged because of bad cooling.

10. MAINTENANCE

Periodic maintenance will keep your generator in the best operating
condition.
Read the instructions before you begin, and make sure you
have the tools and skills required.
Stop the engine before starting maintenance work.
To reduce the possibility of fire or explosion, be careful when
working around gasoline. Use only a nonflammable solvent,
not gasoline, to clean parts. Keep cigarettes, sparks, and
flames away from all fuel-related.
NOTE
If you are not familiar with maintenance work, have an
authorized dealer do it for you.
Allow the engine to cool well, if