  • Page 1 User Guide...
  • Page 2 Energizer Brands, LLC and related subsidiaries and are used under license by Midland Power, Inc. All other brand names are trademarks of their respective owners. Neither Midland Power, Inc. nor Energizer Brands, LLC is affiliated with the respective owners of their trademarks.
  • Page 3 Thanks for choosing the eZV Series! You're excited to power up, so we'll keep this brief. Let's get started!
  • Page 4 THIS PRODUCT MEETS ALL CERTIFICATION REQUIREMENTS FROM:...
  • Page 5 This user guide covers the safety, operation and maintenance procedures for the eZV3500SP. All information in this publication is based on the latest product information available at the time of print.
  • Page 6 Product registration is required for all product support and warranty coverage. Warranty support, operation assistance and product support is provided by Midland Power Inc., a licensed manufacturer of Energizer Generators. Please contact us directly for any warranty ® or service questions.
  • Page 7: Table Of Contents

    TABLE OF CONTENTS 1. Safety 2. Learn About Your Generator 2.1 Component Identification 2.2 Control Panel 2.3 Control Functions 2.4 Make Sure You Have Everything 3. Pre-Operation Check 3.1 Add Oil 3.2 Add Gas 3.3 Prepare the Air Cleaner 4. Starting the Engine 4.1 Starting Your Generator 5.
  • Page 8: Safety

    1. SAFETY Using a generator indoors can KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is poison that you cannot see or smell. NEVER use inside a home Only use OUTSIDE and or garage. EVEN if doors far away from windows, and windows are open.
  • Page 9   Gasoline is a highly flammable and explosive liquid. Refuel in a well ventilated area with the engine stopped.   Use of gasoline with an ethanol content greater than 10% can damage the engine and fuel system and will void the manufacturer’s warranty.  ...
  • Page 10   Connections for standby power to a building’s electrical system must be done by a qualified electrician and must comply with all applicable laws and electrical codes. Improper connections may cause serious injuries to electrical workers during a power outage, and when the utility power is restored, the generator may explode or cause fires.
  • Page 11 Only connect in parallel with an approved Energizer parallel kit to another Energizer model featuring parallel. Attempting to connect other brands or models will void Avoid other generator hazards READ MANUAL BEFORE USE.
  • Page 12: Learn About Your Generator

    2. LEARN ABOUT YOUR GENERATOR This section will show you how to identify key parts of your generator. Going over the terminology below will make sure we’re on the same page. 2.1 COMPONENT IDENTIFICATION Fuel Gauge Fuel Cap Folding Handle Recoil Grip Control Panel Battery...
  • Page 13: Control Panel

    2.2 CONTROL PANEL 1. Power Switch 9. Parallel Port 2. EcoMode Switch 10. AC Breaker 3. Fuel Shutoff 11. 120V 25.0A (L5-30) Receptacle 4. Choke 12. AC Breaker 5. Indicator Lights 13. 120V 20A (5-20) Receptacle 6. DC Breaker 14. Ground Terminal 7.
  • Page 14: Control Functions

    2.3 CONTROL FUNCTIONS AC Circuit Breakers   While the generator is running, the breakers should be put in the ON position.   If the current has exceeded its limits it will automatically pop out to the OFF position. Reduce the electrical load on the generator and push the button back to the ON position.
  • Page 15 Low Oil Indicator Light   The oil alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase reaches an unsafe limit, the oil alert system will automatically shut down the engine (the power switch remains in the ON position).
  • Page 16: Make Sure You Have Everything

    2.4 MAKE SURE YOU HAVE EVERYTHING Make sure your generator has everything listed in the table below. Part Name Quantity Inverter Generator User Guide Spark Plug Wrench - Sleeve Spark Plug Wrench - Bar Multi Screwdriver DC Charging Cable Oil Transfer Tool...
  • Page 17: Pre-Operation Check

    3. PRE-OPERATION CHECK Set the generator on a level surface and the power switch to OFF. 3.1 ADD OIL Max Fill Level Oil Transfer Tool Oil Cap and Dipstick Oil Capacity 18 . Oz. / 0.55L Unscrew and remove the oil maintenance panel. Unscrew the oil dipstick and wipe it off.
  • Page 18 Effective Viscosity Range of Engine Oils 15W-50 Synthetic 5W-30 10W-30 5W-30 0°C °C 32°F °F NOTE   Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine.   Use high quality 4-stroke engine oil, certified to meet or exceed API standard SG, SF, SAE ratings with strong detergents.
  • Page 19: Add Gas

    3.2 ADD GAS DANGER! Gasoline is highly flammable and explosive under certain conditions. Refuel in a well-ventilated area with the engine stopped. Do not smoke or allow open flames or sparks in the area where the generator is being refueled or where gasoline is stored.
  • Page 20: Prepare The Air Cleaner

    3.3 PREPARE THE AIR CLEANER Clean and oil the air filter before your first use. Check the maintenance section for a complete cleaning guide. Cover Screws Air Filter Maintenance Panel Air Filter Air Filter Cover Unscrew and remove the air filter maintenance panel. Unscrew the air filter cover and remove the filter.
  • Page 21: Starting The Engine

    4. STARTING THE ENGINE Using a generator indoors can KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is poison that you cannot see or smell. NEVER use inside a home Only use OUTSIDE and or garage. EVEN if doors far away from windows, and windows are open.
  • Page 22: Starting Your Generator

    4.1 STARTING YOUR GENERATOR NOTE   Ensure all connected appliances are turned off.   Return the starter grip slowly by hand, do not let it snap back. Manual Recoil Start Open Start Open the fuel valve by turning the fuel knob to the OPEN position. Pull the choke out to the start position.
  • Page 23 Carburetor Modification for High Altitude Operation   At high altitudes, the standard carburetor air-fuel mixture will be too rich. Fuel consumption will increase and performance will decrease. A very rich mixture will also foul the spark plug and cause hard starting.  ...
  • Page 24: Generator Use

    5. GENERATOR USE WARNING! Do not connect directly to the building’s electrical system. Doing so may result in electrical shocks, fire, and backfeeding the grid. Connections for standby power to a building’s electrical system must be done by a qualified electrician and must comply with all applicable laws and electrical codes.
  • Page 25: Dc Applications

    5.2 DC APPLICATIONS The DC receptacle may be used for charging 12V batteries only. In DC operation, turn EcoMode OFF. NOTE   The DC receptacle can be used while the AC power is in use. If used at the same time, be sure not to exceed the total power for AC and DC. (AC: Rated Running Watts, DC: 5A)  ...
  • Page 26: Ac Applications

    5.3 AC APPLICATIONS OUTPUT SURCHARGE OVERLOAD PRET A UTILISER LOW OIL HUILE BAS Start engine and make sure output indicator light (READY TO USE) is on. Confirm all electrical appliances are switched off, and connect the appliance plugs to the generator receptacle. Turn on the appliances.
  • Page 27: Ac Parallel Operation

    •••• •• •• •• •• •• •••• •• •• •• •• •• •••• •• •• •• •• •• •••• •• •• •• •• •• 5.4 AC PARALLEL OPERATION •••• •• •• •• •• •• •••• •• •• •• •• •• ••...
  • Page 28: Stopping The Engine

    6. STOPPING THE ENGINE STOP CLOSED Switch off the connected electrical appliances. Turn the power switch to the STOP position or press the OFF button on the remote control. Turn the fuel shutoff to the CLOSED position. NOTE   Make sure the fuel switch is in the CLOSED position when stopping, transporting, and storing the generator.
  • Page 29: Maintenance

    7. MAINTENANCE Proper maintenance keeps your generator in the best operating condition by ensuring safe, economical and trouble-free operation. Only use genuine parts and recommended fluids to replace the worn components. Improper maintenance may cause the generator to malfunction and can lead to serious injury. Contact customer support if you have any maintenance questions.
  • Page 30: Maintenance Schedule

    7.1 MAINTENANCE SCHEDULE Maintain the generator according to the maintenance schedule below. NOTE   Service more frequently when used in dusty areas.   These items should be serviced by an authorized service center, unless you have the proper tools and are mechanically proficient. Refer to manual for service procedures.
  • Page 31: Changing The Oil

    7.2 CHANGING THE OIL WARNING! Used motor oil can cause skin irritations if left in long-term contact with skin. Thoroughly wash off used oil as soon as possible with soap and water. Do not dispose of used oil in drains or on soil. Local service shops provide environmentally-friendly disposal methods.
  • Page 32 Effective Viscosity Range of Engine Oils 15W-50 Synthetic 5W-30 10W-30 5W-30 0°C °C 32°F °F Max Fill Level Oil Transfer Tool Oil Cap and Dipstick Oil Capacity 18 . Oz. / 0.55L NOTE   Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine.
  • Page 33: Cleaning The Air Filter

    7.3 CLEANING THE AIR FILTER WARNING! Using gasoline or other flammable solvents can cause a fire or explosion. Do not operate this product without an air filter. A dirty air filter will restrict air flow into the carburetor. Clean and maintain the air filter regularly, especially in dusty areas.
  • Page 34: Spark Plug Service

    If the foam element is dirty, clean it in warm soapy water, rinse, and allow it to dry thoroughly, or clean in non-flammable solvent and allow to dry. Filter Dip the foam element in clean engine oil, then squeeze out all excess oil. The engine will smoke when started if too much oil is left in the filter.
  • Page 35: Spark Arrester Maintenance

    cracked or chipped. Clean with a wire brush if the spark plug is reused. Measure the spark plug gap with a feeler gauge. The normal value is: 0.6- 0.7mm (0.024- 0.028in). Adjust the gap by carefully bending the electrode. Carefully reinstall the spark plug by hand, to avoid cross-threading. A new spark plug should be tightened 1/2 turn with a spanner.
  • Page 36: Fuel Filter Maintenance

    •••• •• •• •• •• •• •• •• •••• •• •• •• •• •• •• •• •• 7.6 FUEL FILTER MAINTENANCE •••• •• •• •• •• •• •••• •• •• •• •• •• WARNING! •••• •• •• •• •• •• ••••...
  • Page 37: Emission Control System

    7.7 EMISSION CONTROL SYSTEM Emission Source Exhaust gas contains carbon monoxide, nitrogen oxides (NOx) and hydrocarbons. It is very important to control the emissions of NOx and hydrocarbons as they are a major contributor to air pollution. Carbon monoxide is a poisonous gas. The emission of fuel vapors is a source of pollution as well.
  • Page 38 Replacement parts and accessories The parts making up the emission control system in your product’s engine have been specifically approved and certified by the regulatory agencies. You can trust that the replacement parts supplied by customer service have been manufactured to the same production standard as the original parts.
  • Page 39: Transportation & Storage

    8. TRANSPORTATION & STORAGE Draining the Fuel Tank Turn OFF the engine. Remove the fuel cap and the debris screen underneath the fuel cap. Empty the fuel tank using a siphon and an approved gasoline container. Loosen the carburetor drain bolt to discharge all gasoline from inside of the carburetor.
  • Page 40 Storage Gasoline can oxidize in as little as 30 days, causing gum and varnish to build up in fuel system components. NOTE   Ensure that the storage area is free of excess humidity and dust.   To prevent corrosion, coat screws and exposed metal with anti-rust oil at least twice per year.
  • Page 41: Troubleshooting

    9. TROUBLESHOOTING If appliances do not operate: Is the output indicator light ON? Contact an authorized Is the overload indicator light ON? dealer Check the electrical Contact an authorized appliance for any fault dealer Stop the engine and then replace or repair the appliance Restart the engine DC receptacle without any electricity:...
  • Page 42 If the engine does not start: Is there fuel in the tank? Refill the fuel tank. Turn the fuel switch to OPEN. Is the fuel switch OPEN? Turn the power switch to RUN. Is the power switch in RUN? Is there enough oil in the engine? Add the recommended oil.
  • Page 43: Technical Specifications

    Start System Remote, Electric, and Recoil Start Fuel Type Unleaded Gasoline Oil Capacity 18 fl. oz. / 0.55L Oil Type SAE 10W-30 Model Name eZV3500SP Rated Frequency 60Hz Rated Voltage 120V Rated Current 25.0A Rated Speed 2800-3600rpm Max Output Power...
  • Page 44: Wiring Diagram

    11. WIRING DIAGRAM Ignition Module Connector INVERTER BOOSTER PLATE ACTUATOR...
  • Page 45: Appendix

    12. APPENDIX The standard condition of rated power output: Altitude: 0m Ambient temperature: 77°F (25°C) Relative humidity: 30% Factor of Environment Correction: Altitude (m) Ambient Temperature°F (°C) 77° (25°) 86° (30°) 95° (35°) 104° (40°) 113 (45°) 0.98 0.96 0.93 0.90 0.93 0.91...
  • Page 46: Limited Warranty

    13. LIMITED WARRANTY Toll Free: 1-877-528-3772 E-mail: support@energizergenerators.com Online: www.energizergenerators.com Energizer Generator products are distributed by: Midland Power Inc. 376 Magnetic Drive, Toronto, ON M3J 2C4, Canada This product is warranted to be free of defects in material and workmanship for three years from date of purchase.
  • Page 47 Exclusions Not Covered by this Limited Warranty   Normal engine/alternator wear   Damage caused by lack of maintenance as described in the Energizer User Guides, or negligence by using improper or impure motor oil, coolant, or fuel   Damage caused by accidents, improper installation or storage;...
  • Page 48 Batteries Batteries supplied with any generator product should be considered a bonus item and not covered by warranty. Batteries can be damaged by shock, shorting terminals, heat, acid spillage and a number of other factors that cannot be controlled after they have left our facility. It is the customer’s responsibility to take great care when handling a battery so no spillage of acid will occur and cause corrosion;...
  • Page 49 Emission Control System Warranty Parts: This list applies to parts supplied by Midland Power Inc. and does not cover parts supplied by the equipment manufacturer. Please see the original equipment manufacturer’s emissions warranty for non-Midland Power Inc. parts. Consumable parts are covered up to a maximum of 30 days. SYSTEMS COVERED PARTS IN WARRANTY...
  • Page 50 Warranty Claim Procedure Warranty service must be performed by one of our authorized service dealers. Do not return your product where purchased. If you feel your generator is malfunctioning due to a defect or misuse, simply contact our customer support center for technical advice, a warranty claim or general information.
  • Page 51 Enjoy! Be sure to check energizergenerators.com for updates regarding your generator.