electric shock. If it needs to be replaced with another cut-out, the latter must correspond
to the technical specifications of the generator. Due to important mechanical constraints,
it is necessary to use a flexible sheathed cable with a strong rubber protective layer
(conforming to IEC 245-4) or a similar cable. If using an electrical extension cable, the
total length of the extension must not exceed 60m when the section of the wire is
2
1.5mm
and must not exceed 100m when the section of the wire is 2.5mm
Additional requirements for low-power generating sets for use by laymen
•
Protect children by keeping them at a safe distance from the generating set.
•
Fuel is combustible and easily ignited. Do not refuel during operation. Do not
refuel while smoking or near naked flames. Do not spill fuel.
•
Some parts of the internal combustion engine are hot and may cause burns. Pay
attention to the warnings on the generating set.
•
Engine exhaust gases are toxic. Do not operate the generating set in
unventilated rooms. When installed in ventilated rooms, additional
requirements for fire and explosion protection shall be observed.
•
Before use, the generating set and its electrical equipment (including lines and
plug connections) should be checked to ensure that they are not defective.
•
Protection against electrical shock depends on circuit breakers specially
matched to the generating set. If the circuit breakers require replacement, they
should be replaced with a circuit breaker having identical ratings and
performances characteristics.