8. AC PARALLEL OPERATION

Two EZG2000i generators can be operated in parallel to increase the
total available output power reach 3.6 kW. A Parallel Kit 2(optional
equipment) is required for the parallel operation.
1

8.1 START AC PARALLEL

(1). Disconnect or turn off all electrical loads from both generators.
(2). Connect the Parallel Kit 2 between the two EZG2000i generators
Parallel Terminal 1.
(3). Start the engines and make sure the READY LED (green) comes on.
(4). Plug the appliance in receptacles of the Parallel Kit 2.
(5). Turn on the appliance to use.
NOTE
Never connecting the generator in parallel with any other
generator.
Never connect or remove the Parallel Kit 2 when the generator
is running.
For single generator operation, the Parallel Kit 2 must be