When using the remote to do electronic convergence, the following functionality is not available:
•
Lens movement functions
•
Image optimization and setting the aspect ratio
•
Keystone adjustments
•
Customized actions
•
Context-sensitive help
•
On-screen display menu
Follow these steps to adjust convergence electronically with the remote.
1. Before adjusting digital micromirror device (DMD) convergence, make sure the projector has
reached a steady operational state. If switching from a white or bright test pattern to a dark
convergence test pattern, or if warming up the projector after a shutdown, allow 15 minutes
for stabilization so the optics can reach a steady state.
2. On the remote, select Test Pattern and select the E-Convergence test pattern.
The E-Convergence test pattern is displayed, including the instructional text. To remove clutter
from the screen or if familiar with the electronic convergence, turn off the instructional text.
On the remote, select OSD Hide for two seconds.
Until electronic convergence is completed, the displayed image may appear to be blurred and
difficult to read, especially for white text, due to the mis-convergence of the red, green, and
blue pixels.
3. Select the corner sprite you want to adjust first.
By default the top-left position is selected.
Christie Griffyn Series Installation and Setup Guide
020-103314-12 Rev. 1 (07-2023)
Copyright
©
2023 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Installation and setup
48