C1221 - AC Power to Ethernet Hub/switch
An Ethernet Hub or switch is required if you need to use more
than one General Purpose Transceiver (GPT), or if you wish to
connect the echo sounder system to an existing network. Any
commercial 100 MHz Hub/switch may be used.
Cable details, page 111.
C1222 - Battery
This cable is used to connect a battery to the GPT.
The +12 Vdc input/output connectors can be used in the
following ways:
• Operate the transceiver from a +12 Vdc power supply.
• Operate the transceiver from mains power, but leave a battery
connected to the DC connectors. The battery will then
provide you with an uninterruptable power supply facility. It
will automatically be charged when the mains power is
present.
• Use the +12 Vdc power from the transceiver to power
external units.
Cable details, page 81.
C1224 - Ship's ground
This is a single core ground cable. It must be supplied by the
installation shipyard.
Cable details, page 112.
C1226 - New line annotation (trigger input)
This input is referenced to digital ground. The cable must be
provided by the shipyard.
Cable details, page 125.
C1227 - Event annotation (trigger input)
This input is referenced to digital ground. The cable must be
provided by the shipyard.
Cable details, page 125.
C1228 - Remote on/off control
This input is referenced to digital ground. The cable must be
provided by the shipyard.
Cable details, page 122.
If an Hydrographic Operator Station is used, the on/off function
is supported on a dedicated connector.
If a standard computer is used, you must assemble a small
switch box to hold the necessary on/off switch.
Cable layout