Kongsberg EA 600 Instruction Manual page 138

Single beam hydrographic echo sounder
Table of Contents

Advertisement

EA 600 / Base version
Note:
1) All transducer cables must be run in
steel conduits. Use flexible conduit closer
to the transceiver.
2) Cable shields must be connected to
the plug housing.
3) Cable shields must
ship's ground in the junction box.
Single frequency,
single beam
transducer.
W802-6 / Rev.A
128
High power output is achieved when the GPT is equipped with
four transmitter boards. In most systems, this will result in a 4
kW output power, but older GPTs may only be capable of
supplying 2 kW.
The 4 kW high power output is not a standard feature on EA
600.
not
be connected to
Junction Box (1:1)
Single frequency, single beam, high power
Conductors
Screen
Voltage
Max.diameter
The conductor diameter "N" depends on the chosen transducer.
Normal value for single beam transducers is 1.5 mm
transducer cable is available from Kongsberg Maritime.
A
N
B
M
C
L
D
K
E
J
F
H
Outer
Inner
screen
screen
Plug housing
2 x N mm2
Overall braided
600 V
N/A
GPT
A
B
C
D
E
F
H
J
2
. Special
857-164688 / E