EA 600 / Base version
Note
138
4
The crates must not be placed on top of each other, unless
specific markings permit this.
5
The crates must not be placed directly on a dirt-floor.
6
Do not open the crate for inspection unless special
circumstances permit so.
- "Special circumstances" may be suspected damage to
the crate and its content, or inspections by civil
authorities.
- If any units are damaged, prepare an inspection report
stating the condition of the unit and actions taken.
Describe the damage and collect photographic evidence
if possible. Re-preserve the equipment.
- If the units are not damaged, check the humidity
absorbing material. If required, dry or replace the bags,
then repack the unit(s) according to the packing
instructions.
7
If the crate has been opened, make sure that is it closed
and sealed after the inspection.
- Use the original packing material as far as possible.
Refer to information on page 144.
Ambient temperature and humidity
1
The storage room/area must be dry, with a non-condensing
atmosphere. It must be free from corrosive agents.
2
The storage area's mean temperature must not be lower
than -30° C, and not warmer than +70° C.
- If other limitations apply, the crates will be marked
accordingly.
Transducers must not be stored in temperatures below -20° C, or
higher than +60° C.
3
The crate must not be exposed to moisture from fluid
leakages.
4
The crate must not be exposed to direct sunlight or
excessive warmth from heaters.
Shock and vibration
1
The crate must not be subjected to excessive shock and
vibration.
ESD precautions
Refer to the information on page 145.
857-164688 / E