Kongsberg EA 600 Instruction Manual page 141

Single beam hydrographic echo sounder
Table of Contents

Advertisement

Note:
1) All transducer cables must be run in
steel conduits. Use flexible conduit closer
to the transceiver.
2) Cable shields must be connected to
the plug housing.
3) Cable shields must
ship's ground in the junction box.
Single frequency, split beam
transducer
Black
Black
Black
Black
Forward
Ch.3
Ch.4
Port
Starboard
Ch.2
Ch.1
Aft
W802-5 / Rev.C
857-164688 / E
Split beam transducer connected as single beam
The drawing shows how to connect a split beam transducer to a
single beam system.
not
be connected to
Blue
Blue
Blue
Blue
Junction Box (1:1)
Split beam transducer connected as single beam
Conductors
Screen
Voltage
Max.diameter
The conductor diameter "N" depends on the chosen transducer.
Normal value for single beam transducers is 1.5 mm
transducer cable is available from Kongsberg Maritime.
A
N
B
M
C
L
D
K
E
J
F
H
Ch.4
Ch.3
Ch.2
Ch.1
4 x 2 x N mm2
Overall braided
600 V
N/A
Drawing file
Inner
screen
GPT
C
D
Outer
screen
Plug housing
2
. Special
131

Advertisement

Table of Contents
loading

Table of Contents