Compression nut
Figure 40 Cable
gland, type 2
(541-093642)
857-164688 / E
2
Slide the metal washers, the rubber gasket and the
compression nut onto the cable in the order indicated in
the figure.
Refer to figure 40.
3
Bend the screen over the compression cone.
4
Push the compression conne, the washers and the rubber
sealing washer into the cable gland body.
5
Close the mounting nut.
6
Close and tighten the compression nut on the other side of
the cabinet wall.
Female compression cone
(CD3765/093642)
Cable gland body
Metal washers
Compression cone
Rubber sealing
Appendices
Mounting nut