Kongsberg EA 600 Instruction Manual page 137

Single beam hydrographic echo sounder
Table of Contents

Advertisement

Note:
1) All transducer cables must be run in
steel conduits. Use flexible conduit closer
to the transceiver.
2) Cable shields must be connected to
the plug housing.
3) Cable shields must
ship's ground in the junction box.
Single frequency,
single beam
transducer.
W802-1 / Rev.D
857-164688 / E
Single frequency, single beam
The next two drawings show how to connect a single frequency,
single beam transducer to the system. Note that two different
connections are made, depending on the rated power output.
Low power output is achieved when the GPT is equipped with a
single transmitter board. In most systems, this will result in a 2
kW output power, but older GPTs may only be capable of
supplying 1 kW.
not
be connected to
Junction Box (1:1)
Single frequency, single beam, low power
Conductors
Screen
Voltage
Max.diameter
The conductor diameter "N" depends on the chosen transducer.
Normal value for single beam transducers is 1.5 mm
transducer cable is available from Kongsberg Maritime.
A
N
B
M
C
L
D
K
E
J
F
H
Outer
screen
Plug housing
2 x N mm2
Overall braided
600 V
N/A
Drawing file
Inner
screen
GPT
C
D
2
. Special
127