A special protective jacket is used to prevent accidental
contact with conductive parts.
Ingress protection rating is - IP67 according to DSTU EN
60529:2018.
2.3.1.4 Fire safety conditions are ensured by the fact that
the device belongs to compact electronic devices with low
energy consumption, and the absence of combustible materials
used in the structure, and the critical temperature is insufficient
for self-ignition.
2.3.1.5 Direct application of the device is not dangerous for
personnel and is environmentally friendly.
2.3.1.6 In the event of contamination, the device shall be
decontaminated by wiping its surfaces by a gauze swab moistened
with a standard decontaminating agent.
2.3.1.7 Disposal of the device shall be performed in
compliance with the Laws of Ukraine "On Environmental
Protection" and "On Waste", i.e. metal is recycled or melted, and
plastic parts are dumped.
2.3.2 Operating modes of the device
The device has the following modes:
- Switching on/off (2.3.3.1 - 2.3.3.2);
- Measurement and indication of photon ionizing radiation
DER (2.3.3.3);
- Intensity histograms display (2.3.3.4);
- Search diagram display (2.3.3.5);
- Measurement of photon ionizing radiation DE (2.3.3.6);
- Setting up the device (2.3.3.7);
- Mode of data communication with PC (2.3.3.8).
2.3.2.1 To control the operation of the device, according to
Figure 1, two navigation buttons "<", ">" and the ENTER button
are used.
17