Setting Custom Folds; Saving Non-Standard Fold Into Memory; Recalling A Saved Fold From Memory - Formax AutoSeal FD 2094 Operator's Manual

Table of Contents

Advertisement

A) ENTERING A NEW SHEET LENGTH:
1. After 5 seconds the data will be accepted and the last
fold type indicator will start flashing. Select the desired fold
type by pressing the appropriate "FOLD TYPE" button.
2. After 5 seconds the selection will be accepted and the
fold plate stops will move to their new position. During this
period the "PLEASE WAIT" screen will be displayed.
3. When the folder has completed its movement, the single
sheet mode screen will be displayed. At this point, each
time the "SHEET START" button is depressed a single
sheet will be folded and delivered. Any adjustments to fold
lengths or slitter shaft accessories may be made at this
time.
4. Press the "SHEET MODE" button to return to the
production mode. The count screen will be displayed.
5. Accept the displayed sheet length by pressing the
"ENTER" button. This will activate the single sheet mode.
B) DO NOTHING:
After 5 seconds, the count screen will be displayed.
SETTING A CUSTOM FOLD
The 2094/2084 has 3 memory locations that can be used
to store custom fold settings. These will store the plate
settings, the stacker wheel location, and the speed setting
for a fold.
SAVING A NON-STANDARD FOLD INTO MEMORY
1. Set up the fold as you normally would.
2. Once the speed and folds are set the way you want,
press a "MEMORY SET" button. Recall will appear in the
display.
3. Press the (-) button to get to the STORAGE screen.
4. Press the "ENTER" button to store the fold in the memory
location selected.
RECALL A FOLD SAVED TO MEMORY:
1. Press the "MEMORY SET" button that corresponds to the
memory location you wish to recall. RECALL will appear.
2. Press the ENTER button.