Download Print this page

Setting Custom Folds - Formax AutoSeal FD1500 Operator's Manual

Hide thumbs Also See for AutoSeal FD1500:

Advertisement

FOLD PLATE ADJUSTMENT
Upper Fold Plate
(figure 3a)
1. To adjust the first fold remove the top cover. If the first fold is too long loosen the two thumbscrews
on the upper fold plate and slide the bar down. If the fold is too short loosen the thumbscrews and slide
the bar up.
NOTE: The bar should be on the same marks on each side.
2. To adjust the second fold remove the lower fold plate. If the second fold is too long loosen the two
thumbscrews and slide the bar up. If the fold is too short loosen the thumbscrews and slide the bar
down.
NOTE: The bar should be on the same marks on each side.
3.
For quick setup of "C", "Z" and "V" folds refer to the blue lines on the fold plate.

SETTING CUSTOM FOLDS

Eccentric "Z"
1. Measure the length of panel
"A"
2. Adjust the upper fold plate so
that the bar lines up with the
measurements of panel "A" i.e.
if panel "A" is 5 1/4" long move
the bar up or down so that it
lines up with the 5 1/4" mark on
the fold plate.
3. Measure the length of panel
"B"
4. Adjust the lower fold plate so
that the bar lines up with the
measurements of panel "B".
5. Load forms and press start
(refer to OPERATION on page
2).
Thumbscrews
Bar
(figure 3b)
Uneven "C" / Return Mailer
1. Measure the length of panel
"A" & "B"
2. Adjust the upper fold plate so
that the bar lines up with the
Panel "A"
measurements of panel "A" &
"B" i.e. if panel "A" & "B" are 10
1/2" long move the bar up or
down so that it lines up with the
10 1/2" mark on the fold plate.
Panel "B"
3. Measure the length of panel
"B"
4. Adjust the lower fold plate so
that the bar lines up with the
measurements of panel "B".
5. Load forms and press start
(refer to OPERATION on page
2).
3
Lower Fold Plate
*
Extended fold plate is
needed to process this form
Panel "A"
Panel "B"
1-800-543-5454 - www.officezone.com

Advertisement