6.5.6. Number of tanks (NT)
Select the number of tanks.
Options:
•
NT 1: Single tank system;
•
NT 2: Double tanks system.
Mandatory
Due to the 4600 valve being designed for single tank system only, set valve type to 1.
K
Press
or
L
Press
to validate the selection and move to the next parameter.
6.5.7. Tank in service (TS)
Caution
This parameter appears only if number of tanks (NT) is set to 2. If it appears, the 4600 valve
being a single tank system, go back to number of tanks (NT) and set it to 1.
6.5.8. Unit capacity (C)
Set the unit capacity.
Note
The unit capacity parameter is only available if the controller type has been programmed for
volumetric regeneration.
Mandatory
Enter the capacity of the media bed in m
displayed in the upper left corner) or in liters for filter (V is displayed in the upper left
corner).
Note
The unit capacity can be set from 0.1 to 9999 x 1000 °TH*m
grains if DF=GAL.
M Press
or
N
Press
to validate the selection and to move the next parameter.
Ref. MKT-IM-028 / A - 03.07.2018
until "---1" is displayed.
to select the unit capacity.
Installer Manual Fleck 4600 SXT - Programming
3
x °TH or g as CaCO
3
, g as CaCO
for softener system (C is
3
equivalent or in
3
53 / 98