Installer Manual Fleck 4600 SXT - Troubleshooting
10.1. Error detection
Errors codes appear on the service display.
Note
It can take up to 1 minute before an error can be detected and displayed.
10.2. Error types and causes
10.2.1. Motor stall / cam sense error
Note
The valve drive takes more than 6 minutes to go to the next regeneration cycle.
A
Unplug the unit and examine the power head.
B
Verify all circuit board connections.
C
Verify the motor and gearing components are in good condition and
assembled properly.
D
Check the valve and verify that the piston travels freely.
E
Replace / reassemble the various components as necessary.
F
Plug the unit back in and observe its behaviour.
G
If the error reoccurs, unplug the unit.
H
Put it into bypass.
I
Contact your dealer.
10.2.2. Motor run-ON error / cycle sense error
Note
The valve performed an unforeseen cycle.
Note
This error message is only valid until controller version 2.6.
A
Unplug the unit and examine the power head.
B
Verify all circuit board connections.
C
Enter master programming mode.
D
Verify that the valve type and system type are set correctly with regard to
the unit itself.
E
Step the unit to a manual regeneration.
F
Verify that it functions correctly.
G
If the error reoccurs, unplug the unit.
H
Put it into bypass.
I
Contact your dealer.
82 / 98
Ref. MKT-IM-028 / A - 03.07.2018