Valve On Tank Assembly - Pentair FLECK 2850 SXT Installer Manual

Hide thumbs Also See for FLECK 2850 SXT:
Table of Contents

Advertisement

9.4.10

Valve on tank assembly

1. Lubricate the seals with approved silicone grease.
2. Spin the valve (1) onto the tank (2), ensuring the threads are not cross-threaded.
3. Rotate the valve (1) clockwise and freely, without using force until it comes to a stop.
Info
This stop position is considered point zero.
4. Rotate the valve (1) clockwise from point zero to between ¼ turn and ½ turn.
Caution - material
Risk of damage due to excessive force !
Do NOT exceed 27 Nm of torque when installing the valve. Exceeding this limit may
damage the threads and cause failure.
Point 0
Ref. MKT-IM-030 / C - 12.05.2020
Installer manual Fleck 2850 SXT - Maintenance
¼ turn
Point 0
½ turn
85 / 104

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents