Installer Manual Fleck 4600 SXT - Programming
Parameter
Regeneration
VT
flow
Regeneration
CT
control type
NT
Number of tanks
TS
Tank in service
C
Unit capacity
V
Filter capacity
Feedwater
H
hardness
Reserve
RS
selection
SF
Safety factor
Fixed reserve
RC
capacity
DO
Days override
50 / 98
Options
Definition
Std DF single
dF1b
backwash
Std DF double
dF2b
backwash
FLtr
Filter
UFbd
UF brine first
UFlt
UF filter
Othr
Other
Fd
Metered delayed
Metered
FI
immediate
tc
Time clock
dAY
Day of the week
Single tank
1
system
Double tanks
2
system
U1
Tank 1 in service Only displayed for double tanks
U2
Tank 2 in service
0.1 to
°TH*m
9'999'000
1 to 999'900
°TH, ppm or
1 to 1990
grains
SF
Safety factor
Fixed reserve
rc
capacity
0 to 50
0 to 50% of
initial
Litre
capacity
0 to 99
Day
To be used with standard piston only.
Not to be used with 4600.
system.
Only displayed for volumetric
3
regenerations.
L
Only displayed for filter.
Only displayed for volumetric
regenerations.
Only available if set in reserve
%
selection.
Only displayed for volumetric
regenerations and if set in reserve
selection.
Ref. MKT-IM-028 / A - 03.07.2018