9.2.3. Piston and/or brine valve replacement

No.
A
Disconnect the meter cable (1), if available.
B
Using a flat screwdriver, unscrew (5) and remove the cover (4).
C
Using a flat screwdriver, unscrew (3) and remove the washer (2).
Using a flat screwdriver or a 8 mm wrench, unscrew (7) and remove the power head (6)
D
from the valve body (8).
E
Using a flat screwdriver or a 8 mm wrench, unscrew (9) and remove the top plate (10).
F
Remove the brine valve (12) and/or the piston (11).
G
Change the piston (11) and/or the brine valve (12).
H
Reverse above procedure steps to rebuild.