Installer Manual Fleck 4600 SXT - Programming
6.6.
Filter programming
To use the valve as a filter, in the master programming mode, set the regeneration mode (RF) to filter
(FLtr). The controller will let set only the steps necessary to the filter mode, which are: regeneration
control type (CT), days override (DO), regeneration time (RT), backwash (BW), rapid rinse (RR), day of
week (Dn) and current day (CD).
6.7.
Diagnostic
Note
If none of the buttons are pushed for 1 minute in the diagnostic mode the controller returns
to Service mode.
6.7.1. Commands
A
Press and hold
B
Press
or
C
Press
to exit the diagnostic mode at any time.
6.7.2. Current flow rate (FR)
Note
The display is updated every second.
A
Current flow rate display (L/min or gpm depending on display format
programmed):
6.7.3. Peak flow rate (PF)
Note
The controller registers the highest flow rate (L/min) since the last regeneration.
B
Peak flow rate display:
58 / 98
and
for five seconds to enter the diagnostic mode.
to navigate in the diagnostic mode.