6.5.15. Current day (CD)
Set the current day.
Note
The current day is defined from D1(Monday) to D7 (Sunday).
AG Press
or
AH Press
to validate the selection and move to the next parameter.
6.5.16. Flow meter type (FM)
Select the flow meter type.
Options:
•
P0.7: ¾" paddle wheel meter;
•
t0.7: ¾" turbine meter;
•
P1.0: 1" paddle wheel meter;
•
t1.0: 1" turbine meter;
•
P1.5: 1½" paddle wheel meter;
•
t1.5: 1½" turbine meter;
•
P2.0: 2" paddle wheel meter;
•
Gen: generic or other non-Fleck meter.
AI Press
or
AJ Press
to validate the selection and move to the next parameter or exit
master programming mode and save modifications done.
6.5.17. Meter pulse
Set the meter pulse for a non-standard flow meter.
Note
The meter pulse parameter is only available if the Gen option has been set in flow meter type
selection.
AK Press
or
AL Press
to validate the selection and to exit the master programming
mode.
Ref. MKT-IM-028 / A - 03.07.2018
to set the current day.
to select the flow meter type.
to set the meter constant in pulses per unit of volume.
Installer Manual Fleck 4600 SXT - Programming
57 / 98