Manual Rebuild - NEC Express5800/R120g-1E Maintenance Manual

Express server
Hide thumbs Also See for Express5800/R120g-1E:
Table of Contents

Advertisement

Chapter 2 Useful Features
4.6.2

Manual Rebuild

1.
Replace a physical device, and then restart the server.
2.
Run LSI Software RAID Configuration Utility.
3.
From the TOP menu, select Drive Management, and then Select Drive Operations.
The following screen appears.
4.
Confirm that the target physical device is displayed for Select Drive.
By default, Rebuild starts automatically after you replace a physical device.
Tips
Important
Rebuild on the LSI Software RAID Configuration Utility takes long time. Run Rebuild
from the Universal RAID Utility on the OS.
If you need to run Rebuild on the LSI Software RAID Configuration Utility, follow the
procedure below.
Replace a physical device
Run LSI Software RAID Configuration Utility
Perform the Rebuild process
Exit LSI Software RAID Configuration Utility
Express5800/R120g-1E Maintenance Guide