Snmp Alert - NEC Express5800/R120g-1E Maintenance Manual

Express server
Hide thumbs Also See for Express5800/R120g-1E:
Table of Contents

Advertisement

Chapter 2 Useful Features
2.3.4

SNMP Alert

The following menu appears when you select SNMP Alert on BMC Configuration menu.
Item
SNMP Alert
SNMP Alert
Computer Name
Community Name
Alert Process
Alert Acknowledge
Alert Retry Count
Alert Timeout
Alert Reciever1
IP Address1
Alert Reciever2
IP Address2
Alert Reciever3
IP Address3
Alert Level
Alert Level
Alert Test
*1:
When PEF (Platform Event Filter) is set to "Disable" in Miscellaneous menu, SNMP alert is disabled.
*2:
Up to 16 alphanumeric characters are accepted.
*3:
Can be specified only when Alert Acknowledge is set to "Enable".
*4:
When SNMP Alert is enabled, at least one alert receiver should be enabled.
*5:
Can be specified only when each Alert Receiver is set to "Enable".
*6:
Be sure to perform Alert Test after all the parameters are configured appropriately. Alert feature may fail depending on
configuration made for network or alert receiver.
SNMP Alert menu
*1
Enable or disable SNMP Alert.
*2
Specify the Computer Name.
*2
Specify the Community Name.
Select "One Alert Receiver" or "All Alert Receiver" for Alert Process.
Enable or disable Alert Acknowledge.
*3
Specify the count of Alert retry.
Specify the timeout period (in seconds) for alert.
Enable or disable primary receiver.
Specify the IP Address of primary receiver.
Enable or disable secondary receiver.
Specify the IP Address of secondary receiver.
Enable or disable tertiary receiver.
Specify the IP Address of tertiary receiver.
Specify the kind of event to alert.
Error
: When "Error" is detected in each sensor type, the alert is sent to the valid
receiver.
Error, Warning
: When "Error" or "Warning" is detected in each sensor type, the alert is sent
to the valid receiver.
Error, Warning, Information
: When "Error", "Warning" or "Information" is detected in each sensor type,
the alert is sent to the valid receiver.
Separate Setting
: You can arbitrarily select the event to alert in each sensor type.
Execute an alert test by SNMP.
Express5800/R120g-1E Maintenance Guide
Description
*3
*4
*5
*4
*5
*4
*5
*6
2. Server Configuration
Default Value
Disable
Blank
public
One Alert Receiver
Enable
3
6
Enable
0.0.0.0
Disable
0.0.0.0
Disable
0.0.0.0
Error, Warning
115

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800 seriesExp803

Table of Contents