Manual Rebuild - NEC N8100-1410F User Manual

Express5800/120rj-2
Hide thumbs Also See for N8100-1410F:
Table of Contents

Advertisement

4-68 Configuring Your Server

Manual Rebuild

Described below are procedures based on assumption:
One of the HDDs failed in a RAID5 virtual disk configured with three HDDs.
Replace the failed HDD with new one after turning off the power of the server. Auto Rebuild feature
is disabled for non-hot-swap replacement. Use Manual Rebuild feature to recover the virtual disk as
described below.
1.
Start WebBIOS.
Make sure that the status for the replaced HDD is indicated as "UNCONF GOOD" in the
right frame of the Top Menu.
In the example below, the hard disk drive in slot number 2 has been replaced.
The indication "PD Missing from DGx: Slot 2: xxxxx MB" represents that the PD
(physical drive) having been installed in slot number 2 was removed.
2.
Select "():1:2" (newly connected HDD) in [Physical Drives].
3.
The properties for Physical Drive is displayed.

Advertisement

Table of Contents
loading

This manual is also suitable for:

N8100-1411fN8100-1412fN8100-1440fExpress5800/120rj-2

Table of Contents