Planned maintenance
September 2020
3. Install the internal retaining ring holding the bearing assembly into the diffuser.
4. Gently slide the rotor into the bearing shaft. There is an etched "U" on the upstream
5. Install the retaining ring and support fins to the end of the bearing supporting the
72
www.Daniel.com
Figure 9-32: Bearing assembly installation
Figure 9-33: Internal retaining ring installation
side of the rotor.
Important
Handle the rotor with care. Improper handling of the rotor assembly may cause
distortion to the rotor blades, affecting meter performance.
Figure 9-34: Rotor installation
rotor.