Operating conditions and specifications
September 2020
Corrosion, erosion, fatigue, etc.
Decomposition of unstable fluids in operating and test conditions
Possible damage from external fire
Mass of fluid in process and test conditions
WARNING
FUNCTIONAL AND ENVIRONMENTAL HAZARD
Evaluate the functional and environmental conditions prior to installing a turbine meter.
Install the turbine meter in a well designed piping system.
Failure to comply may result in death or serious injury.
2.1.2
Environmental conditions
WARNING
EQUIPMENT HAZARD
Never use this equipment for any purpose other than its intended use.
Failure to comply may result in death, serious injury and/or property damage.
Table 2-2: Environmental conditions
Parameter type
Maximum working pressure
Severe service conditions
Corrosive service
Low and freezing temperatures
Populated areas
Closed, poorly ventilated areas
and combustion sources
Elevation
Humidity
30
Description
This is based on the temperature and pressure rating of the ANSI
B16.5 flanges.
Ensure that piping or other attachments connected to the
turbine meter are not under stress. The design of the turbine
meter has not been assessed for the effects of wind, earthquake
loading and/or other severe weather conditions.
Select the material compatible with specific processes and
atmospheric environments. Implement a periodic inspection
and maintenance program to ensure that pressure-retaining
components are free from corrosion and erosion.
Low specific gravities or high viscosities reduce the flow range of
the turbine meter. Refer to
Operating parameters for the LTM
for more information.
For new installations, locate the turbine meter to an area that
has fewer than 10 buildings intended for human occupancy,
within an area that extends 200 meters (220 yards) radially from
the turbine meter. (Reference: Class 1 location. U.S. DOT, CFR
Title 49: Part 192.5)
Install the turbine meter in a well ventilated area, not less than
one meter (approximately 3 feet) from source of ignition or
source of heat which might damage the unit.
No limit.
No limit.
Daniel Series 1200 Liquid Turbine Meter