Operating Conditions And Specifications; Operating Conditions For The Liquid Turbine Meter - DANIEL 1200 Series User Manual

Liquid turbine meter
Table of Contents

Advertisement

User manual
SERIES 1200 LIQUID TURBINE METER
P/N 3-9008-513
2
Operating conditions and
specifications
2.1
Operating conditions for the liquid turbine
meter
Table 2-1: Operating conditions for the liquid turbine meter
Parameter type
Fluid phase
Fluid(s) measured
Process temperature
(Carbon steel flanges)
Process temperature
(Stainless steel flanges)
Fluid static pressure
Ambient temperature
2.1.1
Design considerations
Some conditions to consider:
Service operating pressure
Service testing pressures
Service process temperature and ambient site temperatures
Chemical composition and fluid toxicity in operating conditions
Traffic, wind and earthquake at loading site
Adverse force or stress caused by inadequate supports, attachments, piping, etc.
26
www.Daniel.com
User manual

Operating conditions and specifications

Description
Liquid
Low viscosity crude oils and condensates
Refined products and intermediates (e.g.: gasoline,
diesel, kerosene, light fuel oils, jet fuel, LPG, butanes,
naphtha, alkylate, reformate, straight run gasoline, cat-
cracked gasoline)
Petrochemicals (e.g.: benzene, toluene, xylenes, cumene,
olefins, pyrolysis gasoline)
Natural gas liquids
-29 ºC to 60 ºC (-20 ºF to 140 ºF)
-40 ºC to 60 ºC (-40 ºF to 140 ºF)
The maximum working pressure for the Daniel Series 1200
Liquid Turbine Meter is based on the temperature/
pressure rating of the ANSI B16.5 flanges. For maximum
working pressures at intermediate temperatures refer to
ANSI B16.5.
-40 ºC to 60 ºC (-40 ºF to 140 ºF) (T
specification)
September 2020
is an electrical
amb
29