Planned maintenance
SERIES 1200 LIQUID TURBINE METER
September 2020
5. Remove the downstream stator and rotor from the bolt.
6. Disassemble all the internals.
62
www.Daniel.com
72
Figure 9-7: Support fins removal
The rotor assembly includes the rotor, two stainless steel ball bearing assemblies
and a spacer between the ball races. The ball races are a loose fit in recesses on the
rotor hub and may fall out. Be careful not to lose any small parts.
Figure 9-8: Downstream stator and rotor removal
Figure 9-9: Internals disassembly